Description
The NI PXI-5122 is a high-performance digitizer, detailed with the part number 190100B-04. This device falls under the category of PXI Oscilloscopes/Digitizers, offering advanced features for a wide range of applications. The model PXI-5122 is specifically designed to deliver exceptional performance and accuracy.
This digitizer boasts a 14-bit resolution, ensuring precise measurement capabilities. It is capable of a 100 MS/s sample rate, allowing for the capture of fast signals with high fidelity. Users have a variety of memory options to choose from, including 8 MB, 32 MB, 256 MB, and 512 MB, providing flexibility in data storage and management.
The input impedance of the PXI-5122 is software selectable between 50 Ω and 1 MΩ, offering versatility in signal acquisition. The input range spans from 200 mVpp to 20 Vpp, accommodating a wide array of signal amplitudes. With a spurious free dynamic range (SFDR) of 75 dBc and a signal-to-noise ratio (SNR) of 62 dB, this digitizer ensures high-quality signal processing.
It supports seven trigger modes, providing users with multiple options for signal capture initiation. The PXI-5122 is compatible with several types of software, including LabVIEW, LabWindows/CVI, and the NI-SCOPE driver, enhancing its utility in various application scenarios. Connection options are ample, featuring 3 BNC female, 9-pin mini-circular DIN, and 2 SMB jack connectors, ensuring easy integration into existing systems. Lastly, the device offers a self-calibration feature, enabling users to maintain measurement accuracy over time.
| Specification | Details |
|---|---|
| Part Number | 190100B-04 |
| Category | PXI Oscilloscopes/Digitizers |
| Model | PXI-5122 |
| Description | NI PXI-5122 14-Bit 100 MHz, 512 MB/ch Digitizer and SMT Software |
| Resolution | 14-bit |
| Sample Rate | 100 MS/s |
| Memory Options | 8 MB, 32 MB, 256 MB, 512 MB |
| Input Impedance | 50 Ω, 1 MΩ (software selectable) |
| Input Range | 200 mVpp to 20 Vpp |
| Spurious Free Dynamic Range | 75 dBc |
| Signal-to-Noise Ratio | 62 dB |
| Trigger Modes | Seven |
| Software Compatibility | LabVIEW, LabWindows/CVI, NI-SCOPE driver |
| Connectors | 3 BNC female, 9-pin mini-circular DIN, 2 SMB jack |
| Calibration | Self
Question 1: What is the resolution of the NI PXI-5122? Question 2: What maximum sample rate does the PXI-5122 support? Question 3: How much memory can the PXI-5122 have per channel? Question 4: What are the input impedance options for the PXI-5122? Question 5: Does the PXI-5122 support self-calibration? |