Description
The PXI-5122 is a high-performance digitizer featuring a 14-Bit, 100 MHz, 32 MB/ch Digitizer & SMT Software. This model, with a part number of 190100C-02, offers a sample rate of 100 MS/s, ensuring accurate and rapid data capture for a variety of applications.
It provides multiple memory options to suit various needs, including 8 MB (778756-01), 32 MB (778756-02), 256 MB (778756-03), and 512 MB (778756-04). The ADC resolution is 14-bit, delivering high-quality data representation. The PXI-5122 boasts a Spurious Free Dynamic Range (SFDR) of 75 dBc and a Signal-to-Noise Ratio (SNR) of 62 dB, ensuring clear signal acquisition with minimal noise interference.
Its input impedance is software selectable between 50 Ω or 1 MΩ, and it can handle an input range from 200 mVpp to 20 Vpp, making it highly versatile for various signal types. The device supports seven trigger modes, allowing for flexible configuration according to specific experimental or testing requirements.
Software compatibility is broad, with support for NI-SCOPE, LabVIEW, and LabWindows/CVI, enabling seamless integration into a variety of development environments. The front panel of the PXI-5122 includes 3 BNC female, 9-pin mini-circular DIN, and 2 SMB jack connectors, providing ample connectivity options for external devices.
Calibration of the PXI-5122 is self-calibrated, with an external calibration recommended every two years to ensure continued accuracy and performance. The device operates within a temperature range of 0 to 55 °C and has a recommended warm-up time of 15 minutes for optimal performance.
The maintenance phase for this model started on December 30, 2022, and it offers
| Specification | Detail |
|---|---|
| Model | PXI-5122 |
| Part Number | 190100C-02 |
| Digitizer Type | 14-Bit, 100 MHz, 32 MB/ch Digitizer & SMT Software |
| Sample Rate | 100 MS/s |
| Memory Options | 8 MB (778756-01), 32 MB (778756-02), 256 MB (778756-03), 512 MB (778756-04) |
| ADC Resolution | 14-bit |
| Spurious Free Dynamic Range | 75 dBc |
| Signal-to-Noise Ratio | 62 dB |
| Input Impedance | Software selectable 50 Ω or 1 MΩ |
| Input Range | 200 mVpp to 20 Vpp |
| Trigger Modes | Seven |
| Software Compatibility | NI-SCOPE, LabVIEW, LabWindows/CVI |
| Front Panel Connectors | 3 BNC female, 9-pin mini-circular DIN, 2 SMB jack |
| Calibration | Self-calibrated; External calibration recommended every two years |
| Temperature Range | 0 to 55 °C |
| Recommended Warm-up Time | 15 minutes |
| Maintenance Phase Start Date | December 30, 2022 |
| Calibration Options | NIST accredited calibrations, Basic in-house calibration |
Question 1: What is the sample rate of the PXI-5122?
Answer 1: 100 MS/s
Question 2: What is the ADC resolution of PXI-5122?
Answer 2: 14-bit
Question 3: How much maximum memory can PXI-5122 support?
Answer 3: 512 MB
Question 4: What are the input impedance options for PXI-5122?
Answer 4: 50 Ω or 1 MΩ
Question 5: What is the maintenance start date for PXI-5122?
Answer 5: December 30, 2022