Description
The Part Number 190100C-04 refers to an advanced PXI Oscilloscopes/Digitizers category product, specifically the Model PXI-5122. This model is a high-performance NI PXI-5122 14-Bit 100 MHz, 512 MB/ch Digitizer accompanied by SMT Software, designed to meet the needs of a wide range of digital signal processing applications.
It boasts a sampling rate of 100 MS/s and a resolution of 14-bit, ensuring precision and clarity in data capture. Users have the flexibility to select from memory options ranging from 8 MB to 512 MB per channel, allowing for extensive data storage and manipulation capabilities. The input impedance can be configured to either 50 Ω or 1 MΩ, software selectable, to match the requirements of various signal types.
Furthermore, the PXI-5122 supports an input range from 200 mVpp to 20 Vpp, accommodating a wide variety of signal amplitudes. With seven trigger modes, this digitizer allows for versatile and precise control over signal acquisition. The device is equipped with front panel connectors including 3 BNC female, 1 9-pin mini-circular DIN, and 2 SMB jack, providing flexibility in connection and integration with other equipment.
Its performance is further enhanced by a Spurious Free Dynamic Range (SFDR) of 75 dBc and a Signal-to-Noise Ratio (SNR) of 62 dB, ensuring high fidelity in signal capture and analysis. The PXI-5122 is compatible with various software including NI-SCOPE, LabVIEW, and LabWindows/CVI, offering extensive support for data analysis and processing.
The device is designed with maintenance in mind, being self-calibrated with an external calibration recommended at least once every two years
| Specification | Detail |
|---|---|
| Part Number | 190100C-04 |
| Category | PXI Oscilloscopes/Digitizers |
| Model | PXI-5122 |
| Description | NI PXI-5122 14-Bit 100 MHz, 512 MB/ch Digitizer and SMT Software |
| Sampling Rate | 100 MS/s |
| Resolution | 14-bit |
| Memory Options | 8 MB to 512 MB per channel |
| Input Impedance | 50 Ω or 1 MΩ (software selectable) |
| Input Range | 200 mVpp to 20 Vpp |
| Trigger Modes | Seven |
| Front Panel Connectors | 3 BNC female, 1 9-pin mini-circular DIN, 2 SMB jack |
| Spurious Free Dynamic Range | 75 dBc |
| Signal-to-Noise Ratio (SNR) | 62 dB |
| Software Compatibility | NI-SCOPE, LabVIEW, LabWindows/CVI |
| Calibration | Self-calibrated; External calibration recommended at least once every two years |
| Operating Temperature Range | 0 to 55 °C |
| Warm-Up Time | 15 minutes |
| Maintenance Phase Start Date | December 30, 2022 |
Question 1: What is the resolution of the PXI-5122?
Answer 1: 14-bit
Question 2: How much memory per channel does PXI-5122 support?
Answer 2: Up to 512 MB/ch
Question 3: What is the maximum input range of the PXI-5122?
Answer 3: 200 mVpp to 20 Vpp
Question 4: What is the SFDR value of the PXI-5122?
Answer 4: 75 dBc
Question 5: How often is external calibration recommended for PXI-5122?
Answer 5: Every two years