Description
The PXI-5142 is a high-performance oscilloscope with various notable specifications. It has part numbers including 195003E-01L, 779587-02, and 779587-01, catering to different configurations and needs. This model features two channels, allowing for simultaneous measurement and analysis of two different signals.
It boasts a data transmission rate of up to 40 MHz and offers different memory sizes depending on the version: 256 MB for the 779587-02 model and 64 MB for the 779587-01 model. With a sampling rate of 100 MS/s, it can accurately capture fast signal changes.
The input impedance is selectable between 50 Ω or 1 MΩ, providing flexibility for various signal types. The input voltage range spans from 200 mV to 20 V, accommodating a wide range of signal amplitudes. It can store over half a million waveforms in its embedded memory, making it ideal for extensive data collection and analysis.
Software compatibility includes LabVIEW, LabWindows/CVI, Measurement Studio, and the NI-SCOPE driver, ensuring seamless integration into existing systems. Configuration is managed through the Measurement & Automation Explorer (MAX) tool, simplifying setup and adjustments.
The device requires a warm-up time of 15 minutes to stabilize and is recommended to undergo calibration annually or every two years for optimal performance. Weighing in at 16.2 oz and measuring 8.5 x 0.8 x 5.1 inches, it is compact and easily integrated into various setups. Lastly, it operates within a temperature range of 0 °C to 45 °C, and its storage temperature range ensures reliability and longevity in diverse environments.
| Specification | Detail |
|---|---|
| Part Numbers | 195003E-01L, 779587-02, 779587-01 |
| Model | PXI-5142 |
| Channels | 2 |
| Data Transmission | Up to 40 MHz |
| Memory Sizes | 256 MB (779587-02), 64 MB (779587-01) |
| Sampling Rate | 100 MS/s |
| Input Impedance | 50 Ω or 1 MΩ, selectable |
| Input Voltage Range | 200 mV to 20 V |
| Waveforms in Embedded Memory | Over half a million |
| Software Compatibility | LabVIEW, LabWindows/CVI, Measurement Studio, NI-SCOPE driver |
| Configuration Tool | Measurement & Automation Explorer (MAX) |
| Warm-up Time | 15 minutes |
| Calibration Period | Annually or every two years (recommended) |
| Weight | 16.2 oz |
| Dimensions | 8.5 x 0.8 x 5.1 in |
| Operating Temperature Range | 0 °C to 45 °C |
| Storage Temperature Range
Question 1: What is the max data transmission rate of PXI-5142? Answer 1: 40 MHz Question 2: Does the PXI-5142 support LabVIEW? Question 3: What are the input impedance options for PXI-5142? Question 4: How much memory does the 779587-02 version of PXI-5142 have? Question 5: What is the recommended calibration interval for PXI-5142? |