img

190353G-48L

This device offers 2 channels, 40 MHz max bandwidth, and 100 MS/s sample rate, with memory options up to 256 MB.

In Stock | Ships Today

img

    Description

    The product features a variety of Part Numbers including 195003E-01L, 779587-02, and 779587-01, catering to diverse requirements and configurations.
    It is equipped with 2 Channels, providing the capability to handle multiple signals simultaneously.

    The device boasts a Maximum Bandwidth of 40 MHz, ensuring high-speed data acquisition and processing.
    With a Sample Rate of 100 MS/s, it captures precise and accurate data points during measurements.

    Memory options vary with part numbers; 256 MB for part number 779587-02 and 64 MB for part number 779587-01, offering flexibility in data storage capacity.
    The Input Impedance is program selectable between 50 Ω or 1 MΩ, allowing for optimal adaptation to different signal sources.

    It supports an Input Range from 200 mV to 20 V, accommodating a wide spectrum of signal amplitudes.
    Furthermore, the device is enabled with Onboard Signal Processing (OSP), enhancing signal analysis and processing capabilities.

    For software compatibility, it works seamlessly with LabVIEW, LabWindows/CVI, and Measurement Studio, offering versatile application development environments.
    The included Driver Software is NI-SCOPE, which facilitates easy integration and operation.

    The Configuration Tool provided is the Measurement & Automation Explorer (MAX), simplifying device setup and configuration.
    A Recommended Warm-Up Time of 15 minutes is suggested for optimal performance stability.

    The device should undergo Calibration Period checks Annually or every two years (recommended) to maintain accuracy and reliability.
    It weighs 16.2 oz and has compact Dimensions of 8

    Question 1: What is the max bandwidth of the PXI-5142?
    Answer 1: 40 MHz

    Question 2: What sample rate does the PXI-5142 offer?
    Answer 2: 100 MS/s

    Question 3: What memory capacity does part number 779587-02 have?
    Answer 3: 256 MB

    Question 4: What input impedance options does the PXI-5142 have?
    Answer 4: 50 Ω or 1 MΩ

    Question 5: How often should the PXI-5142 be calibrated?
    Answer 5: Annually or every two years

    Specification Details
    Part Numbers 195003E-01L, 779587-02, 779587-01
    Channels 2
    Maximum Bandwidth 40 MHz
    Sample Rate 100 MS/s
    Memory Options 256 MB (779587-02), 64 MB (779587-01)
    Input Impedance Program selectable 50 Ω or 1 MΩ
    Input Range 200 mV to 20 V
    Onboard Signal Processing (OSP) Yes
    Compatible Software LabVIEW, LabWindows/CVI, Measurement Studio
    Driver Software NI-SCOPE
    Configuration Tool Measurement & Automation Explorer (MAX)
    Recommended Warm-Up Time 15 minutes
    Calibration Period Annually or every two years (recommended)
    Weight 16.2 oz
    Dimensions 8.5 x 0.8 x 5.1 in.