Description
The PXI-5124 is a high-performance digitizer that offers a variety of specifications to meet the needs of demanding measurement applications. It has an impressive array of part numbers including 778757-01, 778757-02, 778757-03, 778757-04, 191766A-02, 191766C-01, and 191766A-01, ensuring flexibility and compatibility with various setups.
This model boasts a sampling rate of 200 MS/s, allowing for precise and accurate data capture. The device offers multiple memory options, including 8 MB/Ch, 32 MB/Ch, 256 MB/Ch, and 512 MB/Ch, providing ample storage for complex measurements and long-duration captures.
With 2 input channels, the PXI-5124 can handle dual signals simultaneously, enhancing its utility in multi-signal environments. The analog resolution of 12-bit ensures that the data captured is detailed and of high quality.
The data transmission capability of this model is notable as well, with a rate of 150 MHz, facilitating swift and efficient movement of data to where it’s needed. Its module size is 3U PXI, making it a compact and efficient choice for integration into PXI systems.
Compatibility with NI-SCOPE 2.7 driver software further enhances its usability, providing users with powerful tools for data analysis and manipulation. The variety of connectors, including 3 BNC female, 2 SMB Jack, and 1 9-pin mini-circular DIN, offers flexibility in connecting various types of signals.
The calibration interval for the PXI-5124 is every 2 years, ensuring that it remains accurate and reliable over time. A warm-up time of 15 minutes is required for the device to stabilize and perform at its best. The maintenance phase start date was December 30, 2022, marking when the device entered a crucial phase of its lifecycle.
Lastly, it is
| Specification | Detail |
|---|---|
| Part Numbers | 778757-01, 778757-02, 778757-03, 778757-04, 191766A-02, 191766C-01, 191766A-01 |
| Model | PXI-5124 |
| Sampling Rate | 200 MS/s |
| Memory Options | 8 MB/Ch, 32 MB/Ch, 256 MB/Ch, 512 MB/Ch |
| Input Channels | 2 |
| Analog Resolution | 12-bit |
| Data Transmission | 150 MHz |
| Module Size | 3U PXI |
| Driver Software | NI-SCOPE 2.7 |
| Connectors | 3 BNC female, 2 SMB Jack, 1 9-pin mini-circular DIN |
| Calibration Interval | 2 years |
| Warm-up Time | 15 minutes |
| Maintenance Phase Start Date | December 30, 2022 |
| Available for Calibration | Yes, with an average turnaround time of 1 to 2 weeks for NIST accredited calibrations | Question 1: What is the sampling rate of the PXI-5124?