img

195003F-02L

The PXI-5142 is a 2-channel oscilloscope with a 40 MHz bandwidth, 100 MS/s sample rate, and up to 256 MB memory, featuring OSP and NI-SCOPE software.

In Stock | Ships Today

img

    Description

    The PXI-5142 is a digital oscilloscope that comes with part numbers 195003E-01L, 779587-02, and 779587-01. It offers a selection of memory sizes with 256 MB available for the model number 779587-02 and 64 MB for the model number 779587-01. This oscilloscope features 2 channels and provides a maximum bandwidth of 40 MHz, coupled with a sample rate of 100 MS/s.

    Users have the flexibility to select the input impedance between 50 Ω or 1 MΩ, according to their testing requirements. The input range of this device is quite versatile, ranging from 200 mV to 20 V, allowing for a wide variety of signal measurements. An essential feature of the PXI-5142 is its Onboard Signal Processing (OSP), which enhances signal analysis capabilities.

    The device is supported by NI-SCOPE driver software, ensuring seamless integration and operation. It is compatible with various Application Development Environments (ADEs) including LabVIEW, LabWindows/CVI, and Measurement Studio, facilitating a broad range of development options for users. Configuration and management of the PXI-5142 are streamlined through the Measurement & Automation Explorer (MAX) tool.

    Before using the PXI-5142, a warm-up time of 15 minutes is recommended to ensure optimal performance. To maintain accuracy and reliability, a calibration period is suggested annually or every two years. Lastly, the device weighs 16.2 oz, making it a relatively lightweight addition to any testing setup.

    Specification Detail
    Part Numbers 195003E-01L, 779587-02, 779587-01
    Model PXI-5142
    Memory Size 256 MB (779587-02), 64 MB (779587-01)
    Channels 2
    Maximum Bandwidth 40 MHz
    Sample Rate 100 MS/s
    Input Impedance 50 Ω or 1 MΩ (Program selectable)
    Input Range 200 mV to 20 V
    Onboard Signal Processing (OSP) Yes
    Driver Software NI-SCOPE
    Compatible ADEs LabVIEW, LabWindows/CVI, Measurement Studio
    Configuration Tool Measurement & Automation Explorer (MAX)
    Warm-Up Time 15 minutes
    Calibration Period Annually or every two years (recommended)
    Weight 16.2 oz

    Question 1: What are the memory options for the PXI-5142?
    Answer 1: 256 MB for 779587-02, and 64 MB for 779587-01.

    Question 2: What is the maximum bandwidth of the PXI-5142?
    Answer 2: 40 MHz.

    Question 3: What sample rate does the PXI-5142 support?
    Answer 3: 100 MS/s.

    Question 4: Does the PXI-5142 support OSP?
    Answer 4: Yes, it features Onboard Signal Processing.

    Question 5: What software is the PXI-5142 compatible with?
    Answer 5: LabVIEW, LabWindows/CVI, and Measurement Studio.