img

195003G-01L

The PXI-5142 is a 2-channel oscilloscope with up to 40 MHz bandwidth, 100 MS/s sample rate, and features OSP and NI-SCOPE software compatibility.

In Stock | Ships Today

img

    Description

    The PXI-5142 is a high-performance oscilloscope with a range of specifications tailored for precise measurements and analysis. This model has multiple part numbers, including 195003E-01L, 779587-02, and 779587-01, indicating variations in memory and possibly other features.

    Each channel of the PXI-5142 can be equipped with either 64 MB of memory (Part Number: 779587-01) or 256 MB (Part Number: 779587-02), providing flexibility in data storage and manipulation. The device features two channels, allowing for simultaneous measurements of different signals.

    With a bandwidth of up to 40 MHz and a sample rate of 100 MS/s, the PXI-5142 is capable of capturing fast transient signals with high fidelity. Its input impedance is programmable, offering selections between 50 Ω or 1 MΩ to match a wide range of signal sources.

    The input voltage range spans from 200 mV to 20 V, accommodating signals of various amplitudes. Additionally, the device boasts Onboard Signal Processing (OSP), which includes features such as quadrature digital down-conversion (DDC), true digital down-conversion, and anti-alias filtering, enhancing the quality of signal analysis.

    Software compatibility is extensive, supporting NI-SCOPE driver software and integration with popular development environments such as LabVIEW, LabWindows/CVI, and Measurement Studio. Configuration and management of the device are facilitated through the Measurement & Automation Explorer (MAX) tool.

    Before reaching optimal performance, the PXI-5142 requires a warm-up time of 15 minutes. To maintain accuracy, a calibration period is recommended annually or every two years. The unit weighs 16

    Specification Detail
    Product Model PXI-5142
    Part Numbers 195003E-01L, 779587-02, 779587-01
    Memory per Channel 64 MB (Part Number: 779587-01), 256 MB (Part Number: 779587-02)
    Channels 2
    Bandwidth Up to 40 MHz
    Sample Rate 100 MS/s
    Input Impedance Program selectable 50 Ω or 1 MΩ
    Input Voltage Range 200 mV to 20 V
    Onboard Signal Processing (OSP) Yes, includes quadrature digital down-conversion (DDC), true digital down-conversion, and anti-alias filtering
    Software Compatibility NI-SCOPE driver software, compatible with LabVIEW, LabWindows/CVI, Measurement Studio
    Configuration Tool Measurement & Automation Explorer (MAX)
    Warm-up Time 15 minutes
    Calibration Period Annually or every two years (recommended)
    Weight 16.2 oz

    Question 1: What is the bandwidth of the PXI-5142?
    Answer 1: Up to 40 MHz

    Question 2: How many channels does the PXI-5142 have?
    Answer 2: 2 channels

    Question 3: What software is compatible with the PXI-5142?
    Answer 3: NI-SCOPE, LabVIEW, LabWindows/CVI

    Question 4: What is the sample rate of the PXI-5142?
    Answer 4: 100 MS/s

    Question 5: What are the PXI-5142’s input impedance options?
    Answer 5: 50 Ω or 1 MΩ