Description
“`html
The PXI-5142 is a model within the PXI Oscilloscopes/Digitizers category, known for its high precision and performance. This device boasts a significant bandwidth of 100 MHz and a resolution of 14 bits, ensuring detailed and accurate measurements. Its sampling rate is 100 MS/s, offering efficient data acquisition speeds.
Equipped with 2 channels, the PXI-5142 provides versatility for a range of measurement tasks. Additionally, it features 256 MB of memory per channel for the part number 779587-02 and 64 MB for part number 779587-01, allowing for extensive data storage and analysis. The device also supports Onboard Signal Processing (OSP), enhancing its functionality and performance.
The input impedance is selectable between 50 Ω or 1 MΩ, offering flexibility for various signal types. It can handle an input voltage range from 200 mV to 20 V, accommodating a wide array of electrical signals. Moreover, the PXI-5142 is compatible with several software platforms, including LabVIEW, LabWindows/CVI, and Measurement Studio, which facilitates integration into existing systems.
For configuration and setup, the device utilizes the Measurement & Automation Explorer (MAX) tool, simplifying the process of system integration. It requires a warm-up time of 15 minutes before reaching optimal performance levels. To maintain its precision, a calibration is recommended at least once every 2 years.
The part numbers associated with the PXI-5142 include 195003E-01L, 779587-02, and 779587-01, ensuring a range of options to meet specific user requirements and configurations.
“`
| Specification | Detail |
|---|---|
| Part Numbers | 195003E-01L, 779587-02, 779587-01 |
| Model | PXI-5142 |
| Category | PXI Oscilloscopes/Digitizers |
| Bandwidth | 100 MHz |
| Resolution | 14 bits |
| Sampling Rate | 100 MS/s |
| Channels | 2 |
| Memory per Channel | 256 MB (779587-02), 64 MB (779587-01) |
| Onboard Signal Processing (OSP) | Yes |
| Input Impedance | 50 Ω or 1 MΩ (Program Selectable) |
| Input Voltage Range | 200 mV to 20 V |
| Software Compatibility | LabVIEW, LabWindows/CVI, Measurement Studio |
| Configuration Tool | Measurement & Automation Explorer (MAX) |
| Warm-up Time | 15 minutes |
| Calibration Period | Recommended at least once every 2 years |
| Question 1: What is the bandwidth of the PXI-5142? Answer 1: 100 MHz Question 2: How many channels does the PXI-5142 have? Question 3: What is the sampling rate of PXI-5142? Question 4: What software does the PXI-5142 support? Question 5: How often is calibration recommended for the PXI-5142? |