Description
The PXI-5154 is a state-of-the-art PXI Oscilloscope/Digitizer, designated with the part number 190353F-14. This model is renowned for its versatility in application, thanks to its wide array of memory options, including 8 MB (780319-01), 64 MB (780319-02), and 256 MB (780319-03), catering to various data acquisition needs.
With an impressive sample rate of up to 1 GS/s direct, the PXI-5154 ensures high-speed data capture. It features two simultaneously sampled channels, providing the capability to record multiple signals at once. The device utilizes BNC connectors, facilitating easy and reliable connection to a broad range of test probes and accessories.
The PXI-5154 boasts a remarkable bandwidth of 1 GHz, enabling it to accurately measure high-frequency signals. The voltage standing wave ratio (VSWR) is specified at 1.27, indicating efficient signal transmission and minimal reflection.
Calibration is external, ensuring the device maintains its accuracy and reliability over time. Additionally, a self-calibration feature is available on software command, allowing for convenient and quick calibration without the need for external equipment.
Software support is provided by NI-SCOPE Soft Front Panel (SFP) and NI Measurement Automation Explorer (MAX), both of which enhance the user experience by offering intuitive interfaces and powerful automation capabilities.
The maintenance phase for the PXI-5154 began on December 30, 2022, marking the commencement of dedicated support and service for this advanced oscilloscope/digitizer model.
| Feature | Specification |
|---|---|
| Part Number | 190353F-14 |
| Category | PXI Oscilloscopes/Digitizers |
| Model | PXI-5154 |
| Memory Options | 8 MB (780319-01), 64 MB (780319-02), 256 MB (780319-03) |
| Sample Rate | Up to 1 GS/s direct |
| Channels | Two simultaneously sampled channels |
| Connectors | BNC |
| Voltage Standing Wave Ratio | 1.27 |
| Bandwidth | 1 GHz |
| Calibration | External calibration |
| Self-Calibration | Available on software command |
| Software | NI-SCOPE Soft Front Panel (SFP), NI Measurement Automation Explorer (MAX) |
| Maintenance Phase Start Date | December 30, 2022 |
Question 1: What is the bandwidth of the PXI-5154?
Answer 1: 1 GHz
Question 2: What sample rate does the PXI-5154 support?
Answer 2: Up to 1 GS/s
Question 3: How many channels does the PXI-5154 sample simultaneously?
Answer 3: Two
Question 4: What is the VSWR specification of the PXI-5154?
Answer 4: 1.27
Question 5: When did the maintenance phase for the PXI-5154 begin?
Answer 5: December 30, 2022