Description
The Part Number 777950-01 corresponds to the PXI-5401 model, which falls under the category of PXI Arbitrary Waveform Generators. This device boasts a 12-bit amplitude resolution and a frequency resolution of 9.31 mHz, allowing for precise signal generation. With the capability to generate a maximum sine wave frequency of 16 MHz and a max update rate of 40 MHz, it stands out in its performance capabilities.
Regarding the variety of waveforms, the PXI-5401 can produce Sine, Triangle, Square, and Ramp waveforms, providing a broad range of signal types for various testing requirements. The output impedance is software selectable between 50 or 75 Ω, offering flexibility in matching the impedance of the waveform generator to the load. It supports 4 triggering modes, enhancing its versatility in synchronization with other devices or signals.
When it comes to storage, this device can hold up to 16,384 waveforms and 512 frequency steps in its instruction FIFO, making it capable of handling complex waveform sequences. Connectivity is facilitated through two SMB type connectors for external trigger input and PLL reference signal, ensuring easy integration into existing setups.
The power requirements for the PXI-5401 are 3.5 A at 5 V and 125 mA at 12 V, indicating its efficiency in power consumption. It is compatible with various software platforms including LabVIEW, LabWindows/CVI, C, C++, ComponentWorks, and Visual Basic, offering a wide range of development environments for users to operate within. Additionally, calibration services are available, providing NIST accredited calibrations through a 3rd party to ensure accuracy and reliability in measurements.
| Specification | Detail |
|---|---|
| Part Number | 777950-01 |
| Model | PXI-5401 |
| Category | PXI Arbitrary Waveform Generators |
| Amplitude Resolution | 12-bit |
| Frequency Resolution | 9.31 mHz |
| Max Sine Wave Frequency | 16 MHz |
| Max Update Rate | 40 MHz |
| Waveform Types | Sine, Triangle, Square, Ramp |
| Output Impedance | Software selectable 50 or 75 Ω |
| Triggering Modes | 4 |
| Memory | 16,384 waveforms, 512 frequency steps (instruction FIFO) |
| Connectors | Two SMB type (external trigger input and PLL reference signal) |
| Power Requirements | 3.5 A at 5 V, 125 mA at 12 V |
| Software Compatibility | LabVIEW, LabWindows/CVI, C, C++, ComponentWorks, Visual Basic |
| Calibration | Available, NIST accredited calibrations through a 3rd party | Question 1: What is the max sine wave frequency of the PXI-5401?