Description
“`html
The Part Number 192274E-02L refers to a PXI Arbitrary Waveform Generator, specifically the model PXI-5412. This device is designed to generate complex waveforms and is suitable for a wide range of applications. It comes with various Memory Options including 8 MB (779176-01), 32 MB (779176-02), and 256 MB (779176-03) to accommodate different user needs.
The Maximum Bandwidth of the PXI-5412 is 20 MHz, and it supports an Update Rate of 100 MS/s with a Resolution of 14-bit. This high level of precision is further enhanced by the inclusion of Computerized Interpolation, allowing for smoother transitions and more accurate waveform generation.
When it comes to software, the PXI-5412 is supported by NI-FGEN driver software and is compatible with Application Development Environments (ADEs) such as LabVIEW, LabWindows/CVI, and Measurement Studio. This ensures that users can easily integrate the device into their existing setups and workflows.
For optimal performance, a Recommended Warm-Up Time of 15 minutes is suggested before use. Additionally, to maintain accuracy and reliability, a Calibration Period of at least once every 2 years is recommended. This device operates within a temperature range of 0 °C to 55 °C and can be stored between -25 °C to 85 °C.
Finally, the PXI-5412 has been announced to have a Mature Status, meaning it is available for purchase and repairs by Apex Waves. This ensures that users can continue to rely on the device for their waveform generation needs well into the future.
“`
| Specification | Details |
|---|---|
| Part Number | 192274E-02L |
| Category | PXI Arbitrary Waveform Generators |
| Model | PXI-5412 |
| Memory Options | 8 MB (779176-01), 32 MB (779176-02), 256 MB (779176-03) |
| Maximum Bandwidth | 20 MHz |
| Update Rate | 100 MS/s |
| Resolution | 14-bit |
| Computerized Interpolation | Yes |
| Driver Software | NI-FGEN |
| Compatible ADEs | LabVIEW, LabWindows/CVI, Measurement Studio |
| Recommended Warm-Up Time | 15 minutes |
| Calibration Period | At least once every 2 years |
| Operating Temperature Range | 0 °C to 55 °C |
| Storage Temperature Range | -25 °C to 85 °C |
| Mature Status Announcement | Available for purchase and repairs by Apex Waves |
| Calibration Options
Question 1: What is the maximum bandwidth of the PXI-5412? Question 2: How often should the PXI-5412 be calibrated? Question 3: What is the resolution of the PXI-5412? Question 4: Is the PXI-5412 compatible with LabVIEW? Question 5: What is the recommended warm-up time for the PXI-5412? |