Description
The PXI-5421 is a versatile and high-performance waveform generator with multiple part numbers, including 778697-01, 778697-02, 778697-03, and 778697-04. Each of these part numbers corresponds to different memory options available for the device, specifically 8 MB (778697-01), 32 MB (778697-02), 256 MB (778697-03), and 512 MB (778697-04), allowing users to select the memory capacity that best fits their application needs.
With a maximum bandwidth of 43 MHz and a resolution of 16-bit, the PXI-5421 delivers precise and accurate waveform generation. It is capable of a maximum sample rate of 100 MS/s, providing high-speed performance for a variety of testing scenarios. The device features a single output channel with a software-selectable output enable feature, offering flexibility in signal generation.
The PXI-5421 is designed to withstand maximum output overload conditions up to 50 Ω and ±12 V (±8 V for Direct Path) source without sustaining damage, ensuring durability and long-term performance. Users can choose between an internal or external clock source via phase-locked loop or onboard VCXO frequency reference, providing versatility in synchronization and timing.
With a weight of 12.1 oz. and dimensions of 8.5 x 0.8 x 5.1 in, the PXI-5421 is compact and suitable for integration into various test and measurement setups. The device has received a mature status notification from National Instruments but remains available for purchase and repairs through Apex Waves. Additionally, calibration services are available, ensuring that the PXI-5421 maintains its accuracy
| Specification | Detail |
|---|---|
| Part Number(s) | 778697-01, 778697-02, 778697-03, 778697-04 |
| Model | PXI-5421 |
| Memory Options | 8 MB (778697-01), 32 MB (778697-02), 256 MB (778697-03), 512 MB (778697-04) |
| Maximum Bandwidth | 43 MHz |
| Resolution | 16-bit |
| Maximum Sample Rate | 100 MS/s |
| Output Channels | 1 |
| Output Enable Feature | Software-selectable |
| Maximum Output Overload | 50 Ω, ±12 V (±8 V for Direct Path) source without damage |
| Clock Source | Internal or external via phase-locked loop or onboard VCXO frequency reference |
| Weight | 12.1 oz. |
| Dimensions | 8.5 x 0.8 x 5.1 in |
| Mature Status Notification | Announced by National Instruments; available for purchase and repairs by Apex Waves |
| Calibration | Available
Question 1: What is the max memory of PXI-5421? Question 2: How many output channels does PXI-5421 have? Question 3: What is the sample rate of PXI-5421? Question 4: Can PXI-5421 withstand voltage up to ±12 V? Question 5: Is calibration available for PXI-5421? |