Description
The Part Number 778737-01 corresponds to the model PXI-5610, which is categorized under RF Upconverters. This device is capable of operating within a frequency range of 250 kHz to 2.7 GHz, making it versatile for a wide range of radio frequency applications. Additionally, it offers an output power range from -145 dBm to +10 dBm, ensuring adaptability for different signal strength requirements.
With a continuous bandwidth of 20 MHz, the PXI-5610 provides sufficient scope for transmitting wideband signals. Its timebase accuracy is maintained at ±50 ppb, ensuring high precision in frequency generation and modulation. The device supports various reference clock sources, including a high-accuracy OCXO, an external reference clock, and the PXI backplane, offering flexibility in timebase synchronization.
Physical characteristics include a weight of 41.1 oz and compact dimensions of 8.5 x 1.6 x 5.2 inches, making the unit manageable and suitable for integration into various setups. It is designed to be compatible with operating systems such as Windows 2000/NT/XP, ensuring ease of use with common computer systems.
For software integration, it is compatible with LabVIEW, LabWindows/CVI, NI-RFSG, and NI-TUNER, providing a range of options for application development and testing. The recommended calibration interval is either annually or every two years, ensuring that the device maintains its accuracy and reliability over time. Lastly, its operational temperature range is from 0 °C to 55 °C, allowing it to function efficiently in various environmental conditions.
| Specification | Details |
|---|---|
| Part Number | 778737-01 |
| Model | PXI-5610 |
| Category | RF Upconverters |
| Frequency Range | 250 kHz to 2.7 GHz |
| Output Power Range | -145 dBm to +10 dBm |
| Continuous Bandwidth | 20 MHz |
| Timebase Accuracy | ±50 ppb |
| Reference Clock Sources | High-accuracy OCXO, External reference clock, PXI backplane |
| Weight | 41.1 oz |
| Dimensions | 8.5 x 1.6 x 5.2 in |
| Operating System Compatibility | Windows 2000/NT/XP |
| Software Compatibility | LabVIEW, LabWindows/CVI, NI-RFSG, NI-TUNER |
| Calibration Interval | Recommended annually or every two years |
| Temperature Range | 0 °C to 55 °C |
Question 1: What is the frequency range of the PXI-5610?
Answer 1: 250 kHz to 2.7 GHz
Question 2: What continuous bandwidth does PXI-5610 offer?
Answer 2: 20 MHz
Question 3: What is the output power range of the PXI-5610?
Answer 3: -145 dBm to +10 dBm
Question 4: What is the timebase accuracy of PXI-5610?
Answer 4: ±50 ppb
Question 5: What operating systems is the PXI-5610 compatible with?
Answer 5: Windows 2000/NT/XP