Description
The PXI-5660, with part number 778284-01, stands as a robust and versatile spectral analysis device designed for a broad spectrum of applications. It operates within a frequency range of up to 2.7 GHz and is equipped with a memory capacity of 32 MB, catering to the needs of complex data processing and storage.
Housed in a 3U PXI form factor, it provides wide real-time data bandwidth capabilities, ensuring rapid and efficient signal processing. The time base stability of the PXI-5660 is highly stable, enabling precise measurements over time without significant drift.
For software integration, the device is supported by the NI Spectral Measurement Toolkit for LabVIEW and LabWindows/CVI, which simplifies the development of custom measurement and analysis solutions. This toolkit facilitates a range of common measurements such as power spectrum, power peak and frequency, band power, adjacent channel power, and bandwidth, making it highly versatile in application.
The PXI-5660 is suitable for various applications including scientific research, communications, consumer electronics, aerospace/defense, semiconductor testing, software-defined radio (SDR), RFID, and remote sensor networks. This broad applicability highlights the device’s flexibility and capability in addressing diverse measurement requirements.
With a maximum input level of +30 dBm and a minimum detectable signal of less than -130 dBm, the device ensures high sensitivity and dynamic range. Additionally, the input attenuation range of up to 50 dB, selectable in 10 dB steps, allows for precise control over signal input levels, further enhancing the device’s adaptability to varied testing scenarios.
| Specification | Details |
|---|---|
| Part Number | 778284-01 |
| Model | PXI-5660 |
| Frequency Range | Up to 2.7 GHz |
| Memory Capacity | 32 MB |
| Form Factor | 3U PXI |
| Data Bandwidth | Wide (Real-time) |
| Time Base Stability | Highly stable |
| Software Tools | NI Spectral Measurement Toolkit for LabVIEW and LabWindows/CVI |
| Common Measurements | Power spectrum, power peak and frequency, band power, adjacent channel power, bandwidth |
| Applications | Scientific research, communications, consumer electronics, aerospace/defense, semiconductor testing, SDR, RFID, remote sensor networks |
| Maximum Input Level | +30 dBm |
| Minimum Detectable Signal | < -130 dBm |
| Input Attenuation Range | Up to 50 dB (selectable in 10 dB steps) |
Question 1: What is the frequency range of the PXI-5660?
Answer 1: Up to 2.7 GHz
Question 2: How much memory does the PXI-5660 have?
Answer 2: 32 MB
Question 3: What form factor is the PXI-5660?
Answer 3: 3U PXI
Question 4: Can the PXI-5660 be used for RFID applications?
Answer 4: Yes, it’s suitable for RFID.
Question 5: What is the part number of PXI-5660?
Answer 5: 778284-01