Description
The Part Number 778283-01 refers to a sophisticated piece of technology categorized under RF Downconverters, specifically the Model PXI-5600. This device stands out for its Real-time Bandwidth capability of 20 MHz, making it suitable for a wide range of applications. It operates across an impressive Operating Range from 9 kHz to 2.7 GHz, designed to cater to diverse needs within the RF spectrum.
One of its remarkable features is its Noise Density, which is less than -140 dBm/Hz, ensuring high-quality signal processing with minimal noise interference. The Spurious-Free Dynamic Range is another highlight, offering greater than 80 dB, which is indicative of the device’s ability to handle a wide range of signal levels without distortion. Additionally, the Phase Noise performance is exceptional, with less than -94 dBc/Hz at 10 kHz offset, ensuring the purity of the signal.
The Frequency Stability of ±20 ppb and Frequency Accuracy of ±50 ppb are testaments to the device’s precision in frequency measurement and generation. This is further supported by the Timebase, which is an Ultra-high Stability 10 MHz OCXO, providing a reliable reference for frequency generation and measurement.
Compatibility with software is critical for modern RF devices, and the PXI-5600 excels with support for NI-RFSA 2.1, NIPXI-5600 Support, LabVIEW, LabWindows/CVI, Microsoft C/C++, ensuring it can be integrated into a wide range of systems and workflows.
The device is equipped with multiple Connectors including FREQ REF IN, 10 MHz OUT, PXI 10 MHz I/O, OUTPUT, and INPUT, offering flexibility in connectivity for various applications. It is recommended to allow a Warm-Up Time of 20 minutes for optimal performance, and it requires a Calibration Period annually or every
| Specification | Detail |
|---|---|
| Part Number | 778283-01 |
| Category | RF Downconverters |
| Model | PXI-5600 |
| Real-time Bandwidth | 20 MHz |
| Operating Range | 9 kHz to 2.7 GHz |
| Noise Density | < -140 dBm/Hz |
| Spurious-Free Dynamic Range | > 80 dB |
| Phase Noise | < -94 dBc/Hz at 10 kHz offset |
| Frequency Stability | ±20 ppb |
| Frequency Accuracy | ±50 ppb |
| Timebase | Ultra-high Stability (10 MHz OCXO) |
| Software Compatibility | NI-RFSA 2.1, NIPXI-5600 Support, LabVIEW, LabWindows/CVI, Microsoft C/C++s |
| Connectors | FREQ REF IN, 10 MHz OUT, PXI 10 MHz I/O, OUTPUT, INPUT |
| Recommended Warm-Up Time | 20 minutes |
| Calibration Period | Annually or every
Question 1: What is the bandwidth of the PXI-5600? Question 2: What is the operating range of the PXI-5600? Question 3: How low is the noise density of the PXI-5600? Question 4: What is the phase noise of the PXI-5600 at 10 kHz offset? Question 5: What software supports the PXI-5600? |