img

186058G-01

The PXI-5600, part number 778283-01, is an RF Downconverter with a 20 MHz bandwidth, supporting frequencies from 9 kHz to 2.7 GHz.

In Stock | Ships Today

img

    Description

    The 778283-01 is a model PXI-5600 RF downconverter that falls under the category of RF Downconverters. This device is capable of providing a real-time bandwidth of 20 MHz, making it suitable for a wide range of applications. It operates over a frequency range from 9 kHz to 2.7 GHz, ensuring versatility across various RF bands.

    One of its notable technical specifications is the average noise density, which is less than -140 dBm/Hz, and the phase noise, which is less than -94 dBc/Hz at a 10 kHz offset. These features contribute to the device’s ability to deliver high-quality signal processing capabilities. Additionally, the timebase stability is maintained at ±20 ppb, and the frequency accuracy is within ±50 ppb, ensuring precise operations.

    The spurious-free dynamic range is greater than 80 dB, highlighting the device’s ability to maintain signal integrity. Moreover, it provides a measurement repeatability of less than 0.2 dB with a -30 dBm input, indicating its consistency in performance. Compatibility with NI-RFSA 2.1 and NIPXI-5600 Support driver software ensures ease of integration and operation within the National Instruments ecosystem.

    It features multiple connectors, including FREQ REF IN, 10 MHz OUT, PXI 10 MHz I/O, OUTPUT, and INPUT, providing versatility in connectivity options. The required warm-up time for the device is 20 minutes, after which it is fully operational. For maintenance, a calibration frequency of either annually or every two years is recommended to ensure optimal performance.

    Question 1: What is the bandwidth of the PXI-5600?
    Answer 1: 20 MHz

    Question 2: What is the frequency range of the PXI-5600?
    Answer 2: 9 kHz to 2.7 GHz

    Question 3: What is the average noise density of the PXI-5600?
    Answer 3: <-140 dBm/Hz Question 4: What is the phase noise of the PXI-5600 at 10 kHz offset?
    Answer 4: <-94 dBc/Hz Question 5: How often should the PXI-5600 be calibrated?
    Answer 5: Annually or every two years

    Specification Details
    Part Number 778283-01
    Category RF Downconverters
    Model PXI-5600
    Real-time Bandwidth 20 MHz
    Frequency Range 9 kHz to 2.7 GHz
    Average Noise Density < -140 dBm/Hz
    Phase Noise < -94 dBc/Hz at 10 kHz offset
    Timebase Stability ±20 ppb
    Frequency Accuracy ±50 ppb
    Spurious-free Dynamic Range > 80 dB
    Measurement Repeatability < 0.2 dB with -30 dBm input
    Software Compatibility NI-RFSA 2.1, NIPXI-5600 Support driver
    Connectors FREQ REF IN, 10 MHz OUT, PXI 10 MHz I/O, OUTPUT, INPUT
    Warm-up Time 20 minutes
    Calibration Frequency Annually or every two years