Description
The Part Number 778283-01 refers to a high-performance RF Downconverter categorized under RF Downconverters. This particular model, the PXI-5600, is designed to offer exceptional signal processing capabilities for a wide range of applications.
The Real-Time Bandwidth of the PXI-5600 is 20 MHz, providing sufficient bandwidth for most RF signal analysis tasks. It operates over a frequency range from 9 kHz to 2.7 GHz, making it versatile for various signal environments.
One of the key performance metrics of the PXI-5600 is its Noise Density, which is rated at < -140 dBm/Hz, and its Phase Noise, coming in at < -94 dBc/Hz at 10 kHz offset. These specifications ensure that the device can handle signals with low noise levels, making it ideal for sensitive measurements.
The device boasts an Intermodulation Spurious-Free Dynamic Range of > 80 dB, ensuring that it can accurately process signals without intermodulation distortion. Its Timebase Stability is ±20 ppb, with a Timebase Accuracy of ±50 ppb, indicating high precision in time-related measurements.
To operate, the PXI-5600 requires specific software, including NI-RFSA 2.1, NIPXI-5600 Support, ADE (LabVIEW, LabWindows/CVI, Microsoft C/C++). This requirement ensures users have access to a comprehensive suite of tools for managing and analyzing RF signals.
The model is equipped with various Connectors, including FREQ REF IN, 10 MHz OUT, PXI 10 MHz I/O, OUTPUT, INPUT, which provide flexibility in connecting to different RF sources and equipment. It has a Warm-Up Time of 20 minutes, ensuring it reaches operational stability quickly.
For maintenance and accuracy, the device requires a Calibration Period of either
| Specification | Detail |
|---|---|
| Part Number | 778283-01 |
| Category | RF Downconverters |
| Model | PXI-5600 |
| Real-Time Bandwidth | 20 MHz |
| Operating Range | 9 kHz to 2.7 GHz |
| Noise Density | < -140 dBm/Hz |
| Phase Noise | < -94 dBc/Hz at 10 kHz offset |
| Intermodulation Spurious-Free Dynamic Range | > 80 dB |
| Timebase Stability | ±20 ppb |
| Timebase Accuracy | ±50 ppb |
| Software Requirement | NI-RFSA 2.1, NIPXI-5600 Support, ADE (LabVIEW, LabWindows/CVI, Microsoft C/C++) |
| Connectors | FREQ REF IN, 10 MHz OUT, PXI 10 MHz I/O, OUTPUT, INPUT |
| Warm-Up Time | 20 minutes |
| Calibration Period | Annually or every two years |
| Dimensions | 3.
Question 1: What is the frequency range of the PXI-5600? Question 2: What is the real-time bandwidth of the PXI-5600? Question 3: How often does the PXI-5600 require calibration? Question 4: What is the noise density rating of the PXI-5600? |