Description
The product with the part number 778283-01 is a state-of-the-art RF Downconverter, specifically the PXI-5600 model. It is designed to deliver exceptional performance in signal processing with a real-time bandwidth capacity of 20 MHz. This device operates over a wide frequency range from 9 kHz to 2.7 GHz, making it versatile for various applications.
One of its notable features is the noise density, which is less than -140 dBm/Hz, coupled with a phase noise of less than -94 dBc/Hz at a 10 kHz offset. Such specifications ensure high-quality signal fidelity and minimal signal interference, crucial for accurate measurements and analysis.
The PXI-5600 boasts an ultra-high stability timebase frequency stability of ±20 ppb and a frequency accuracy of ±50 ppb, ensuring precise frequency measurements and stability over time. Its intermodulation spurious-free dynamic range is greater than 80 dB, highlighting its ability to handle high-power signals without distortion.
For software compatibility, it requires NI-RFSA 2.1, NIPXI-5600 Support driver, and an Application Development Environment such as LabVIEW, LabWindows/CVI, or Microsoft C/C++, providing flexibility in programming and integration into existing systems.
The device is equipped with various connectors including FREQ REF IN, 10 MHz OUT, PXI 10 MHz I/O, OUTPUT, and INPUT ports for versatile connectivity options. It has a recommended warm-up time of 20 minutes and requires calibration periodically, either annually or every two years, to maintain its high performance and accuracy.
| Specification | Detail |
|---|---|
| Part Number | 778283-01 |
| Category | RF Downconverters |
| Model | PXI-5600 |
| Real-Time Bandwidth Capacity | 20 MHz |
| Operating Frequency Range | 9 kHz to 2.7 GHz |
| Noise Density | < -140 dBm/Hz |
| Phase Noise | < -94 dBc/Hz at 10 kHz offset |
| Ultra-High Stability Timebase Frequency Stability | ±20 ppb |
| Frequency Accuracy | ±50 ppb |
| Intermodulation Spurious-Free Dynamic Range | > 80 dB |
| Software Requirements | NI-RFSA 2.1, NIPXI-5600 Support driver, Application Development Environment (LabVIEW, LabWindows/CVI, Microsoft C/C++) |
| Connectors | FREQ REF IN, 10 MHz OUT, PXI 10 MHz I/O, OUTPUT, INPUT |
| Recommended Warm-Up Time | 20 minutes |
| Calibration Period | Annually or every two years |
| Dimensions