Description
The NI PXI-6115 Multifunction I/O and NI-DAQ (High Memory Option) carries the part number 778204-01 and falls within the category of PXI Multifunction DAQ. This model, designated as PXI-6115, is equipped with 4 differential analog input channels, delivering a resolution of 12 bits. It supports a maximum sample rate of 10 MS/s per channel, ensuring rapid data acquisition and processing. Additionally, the device features 2 analog output channels and 8 digital I/O lines, enhancing its versatility for various applications.
The analog input section of the device benefits from a FIFO buffer size of 32 MS, accommodating extensive data collection without immediate processing. Input ranges are quite flexible, ranging from 0.2 to 42 V, which allows for the measurement of signals of varying amplitudes. To ensure signal integrity, the device incorporates 2 analog filters (3-pole Bessel) with cutoff frequencies of 50 kHz and 500 kHz, respectively. For tasks requiring precise timing and counting, the PXI-6115 provides two 24-bit counter/timers.
For optimal performance, it is recommended to allow a warm-up time of 15 minutes before using the device. To maintain accuracy and reliability, a calibration period of at least once a year is advised. The PXI-6115 is designed to operate within a temperature range of 0 °C to 50 °C, ensuring robust performance across a wide range of environmental conditions. This makes the PXI-6115 an indispensable tool for engineers and researchers requiring high-performance data acquisition and signal processing capabilities.
| Specification | Detail |
|---|---|
| Part Number | 778204-01 |
| Category | PXI Multifunction DAQ |
| Model | PXI-6115 |
| Description | NI PXI-6115 Multifunction I/O and NI-DAQ (High Memory Option) |
| Analog Input Channels | 4 differential |
| Resolution | 12 bit |
| Maximum Sample Rate | 10 MS/s/channel |
| Analog Output Channels | 2 |
| Digital I/O Lines | 8 |
| Analog Input FIFO Buffer Size | 32 MS |
| Input Ranges | 0.2 to 42 V |
| Analog Filters | 2 (3-pole Bessel, 50 kHz and 500 kHz) |
| Counter/Timers | Two 24-bit |
| Recommended Warm-Up Time | 15 minutes |
| Calibration Period | At least once a year |
| Operating Temperature Range | 0 °C to 50 °C | Question 1: What is the part number of the PXI-6115?