Description
The NI PXI-6120 S Series Multifunction DAQ Module is a comprehensive data acquisition system designed for a wide range of applications. This module is identified by its part numbers 778396-01 and 187677C-01, falling under the category of PXI Multifunction DAQ. It is specifically modeled as PXI-6120, signifying its unique design and capabilities.
This DAQ module boasts 4 input channels and 2 output channels, allowing for efficient data input and output operations. Additionally, it is equipped with 8 DIO channels and 2 counter channels, further enhancing its versatility in handling various signals and data types. The sample rate of this module reaches up to 1 MS/s, ensuring rapid data acquisition, while its 16-bit resolution guarantees high precision in measurements.
The connectivity options for this DAQ module are facilitated through a 68-pin male SCSI-II type I/O connector, providing a reliable and secure connection. Furthermore, it is designed with physical dimensions of 6.3 x 3.9 inches, making it a compact yet powerful component suitable for a multitude of setups. The module operates optimally within a temperature range of 0 °C to 50 °C, and its storage temperature range extends from -20 °C to 70 °C, ensuring durability and reliability under various environmental conditions.
The maintenance phase for the NI PXI-6120 started on March 31, 2022, indicating the company’s commitment to providing ongoing support and service for this module. Calibration options include NIST accredited calibrations through a 3rd party, along with basic calibration services, ensuring that the module remains accurate and reliable over time.
| Specification | Detail |
|---|---|
| Part Numbers | 778396-01, 187677C-01 |
| Category | PXI Multifunction DAQ |
| Model | PXI-6120 |
| Description | NI PXI-6120 S Series Multifunction DAQ Module |
| Input Channels | 4 |
| Output Channels | 2 |
| DIO Channels | 8 |
| Counter Channels | 2 |
| Sample Rate | 1 MS/s |
| Resolution | 16-bit |
| I/O Connector | 68-pin male SCSI-II type |
| Physical Dimensions | 6.3 x 3.9 in. |
| Operating Temperature Range | 0 °C to 50 °C |
| Storage Temperature Range | -20 °C to 70 °C |
| Maintenance Phase Start Date | March 31, 2022 |
| Calibration Options | NIST accredited calibrations through a 3rd party; Basic (un
Question 1: What are the input and output channel counts of the PXI-6120? Question 2: What is the sample rate of the PXI-6120? Question 3: What type of connector does the PXI-6120 use? Question 4: What is the operating temperature range of the PXI-6120? Question 5: When did the maintenance phase for the PXI-6120 begin? |