The PXI-6040E is a 12-bit multifunction DAQ with 16 input channels, 500 kS/s rate, and LabVIEW integration, now obsolete but supported by Apex Waves.

In Stock | Ships Today

img

    Description

    The PXI-6040E is a multifunction DAQ device designed for a variety of applications within the PXI form factor. This device comes with part numbers 777484-01 and 184361A-01, making it versatile for different setups and requirements.

    It offers a 12-Bit resolution, ensuring accurate data acquisition for your measurement needs. Users have the flexibility to utilize 16 single-ended or 8 differential analog input channels, catering to a wide range of signal types. With a maximum sampling rate of 500 kS/s, the PXI-6040E is capable of handling high-speed data logging, making it suitable for dynamic measurements.

    The device provides two analog outputs, allowing for straightforward signal generation or actuation based on the acquired data. Additionally, it supports software controlled single point input up to 50 kHz with NI-DAQ, offering precise control over data acquisition processes. Integration with LabVIEW is seamless, enabling users to develop custom applications and interfaces for their specific needs.

    With a measurement sensitivity of 0.008 mV, the PXI-6040E can detect very small changes in signal, making it ideal for precision measurement tasks. The I/O connectivity is provided through a 68-pin male 0.050 D-type connector, ensuring reliable and robust connection to external devices and sensors.

    The external trigger input impedance is 10 kΩ, accommodating a wide range of external triggering sources. Users can select from non-referenced single-ended, differential single-ended, or referenced single-ended (RSE) input modes, providing flexibility in accommodating different signal types. The onboard NI PGIA (Programmable Gain Instrument Amplifier) allows for accurate signal amplification and conditioning.

    For optimal performance, a recommended warm-up time of 15 minutes is advised. To maintain accuracy and reliability, calibration is recommended at least once a year. The PXI-6040E has physical dimensions of 6.3 x 3.9 in., making it compact and suitable

    Specification Detail
    Part Number 777484-01, 184361A-01
    Category PXI Multifunction DAQ
    Model PXI-6040E
    Resolution 12-Bit
    Analog Input Channels 16 single-ended or 8 differential
    Maximum Sampling Rate 500 kS/s
    Analog Outputs 2
    Software Controlled Single Point Input Up to 50 kHz with NI-DAQ
    LabVIEW Integration Yes
    Measurement Sensitivity 0.008 mV
    I/O Connector 68-pin male 0.050 D-type
    External Trigger Input Impedance 10 kΩ
    Input Modes Non-referenced single-ended, Differential single-ended, Referenced single-ended (RSE)
    Amplifier NI PGIA (Programmable Gain Instrument Amplifier)
    Recommended Warm-Up Time 15 minutes
    Calibration At least once a year
    Physical Dimensions 6.3 x 3.9 in.
    Operating Temperature Range 0° to 55° C
    Obsolete Status Announced by National Instruments, available for purchase and repairs by Apex Waves

    Question 1: What is the max sampling rate of PXI-6040E?
    Answer 1: 500 kS/s

    Question 2: How many analog input channels does PXI-6040E have?
    Answer 2: 16 single-ended or 8 differential

    Question 3: What resolution does PXI-6040E offer?
    Answer 3: 12-Bit

    Question 4: Does PXI-6040E support LabVIEW integration?
    Answer 4: Yes

    Question 5: What is the recommended warm-up time for PXI-6040E?
    Answer 5: 15 minutes