Description
The Part Number 191855D-03 corresponds to a PXI Multifunction DAQ device, specifically the PXI-6123 model. This device is capable of a sample rate of 500 kS/s and boasts a resolution of 16 bits. The absolute accuracy of this model is 4.96 mV, ensuring precise measurements.
For optimal performance, the PXI-6123 requires a warm-up time of 15 minutes. It is recommended that the device undergoes calibration every 2 years to maintain accuracy, utilizing NI-MCal calibration technology. This model features 8 analog input channels and 8 DIO channels, along with 2 counters. However, it does not provide any analog output channels.
The PXI-6123 incorporates NI-STC3 timing technology for precise timing operations. It supports a variety of programming interfaces, including DAQExpress, C, C#, Python, LabVIEW, and others, offering flexibility in application development. The model has been announced as part of its mature status, indicating its availability in the market for technological and industrial applications.
| Specification | Detail |
|---|---|
| Part Number | 191855D-03 |
| Category | PXI Multifunction DAQ |
| Model | PXI-6123 |
| Sample Rate | 500 kS/s |
| Resolution | 16 bits |
| Absolute Accuracy | 4.96 mV |
| Warm-up Time | 15 minutes |
| Calibration Interval | 2 years |
| Analog Input Channels | 8 |
| DIO Channels | 8 |
| Counters | 2 |
| Analog Output Channels | None |
| Calibration Technology | NI-MCal |
| Timing Technology | NI-STC3 |
| Programming Interfaces | DAQExpress, C, C#, Python, LabVIEW, etc. |
| Mature Status | Announced |
Question 1: What is the sample rate of the PXI-6123?
Answer 1: 500 kS/s
Question 2: How often does the PXI-6123 need calibration?
Answer 2: Every 2 years
Question 3: What is the resolution of PXI-6123?
Answer 3: 16 bits
Question 4: Does the PXI-6123 have analog output channels?
Answer 4: No
Question 5: Which programming interfaces does PXI-6123 support?
Answer 5: DAQExpress, C, C#, Python, LabVIEW, etc.