Description
The PXI Multifunction DAQ, model PXI-6052E, is identified by part numbers 777962-01 and 186408E-01. This device is capable of handling 16 single-ended or 8 differential channels, which are software selectable. It features a 16-Bit resolution, ensuring precise data acquisition.
The maximum sampling rate of the device reaches up to 333 kS/s, allowing for high-speed data capture. It comes equipped with 2 analog outputs, providing versatility in signal generation. The device supports both analog and digital triggering, enabling users to initiate data acquisition based on specific signal conditions.
Additionally, the PXI-6052E includes 8 digital I/O lines for interfacing with other digital devices. It can accommodate 15 different analog input signal ranges, offering flexibility in signal measurement. The device also features 2 24-bit counters/timers, enhancing its capability for precise timing and counting operations.
Regarding input ranges, the device can handle ±10 V (bipolar) for a 20 V input range and ±50 mV (bipolar), as well as 0 to 100 mV (unipolar) for a 100 mV input range. Its transfer characteristics are rated at ±1.5 (typical) and ±3 (maximum) LSB, ensuring accurate data transfer. Lastly, the PXI-6052E includes a frequency scaler of 1 and possesses trigger lines for enhanced control over data acquisition processes.
| Specification | Detail |
|---|---|
| Part Number | 777962-01, 186408E-01 |
| Category | PXI Multifunction DAQ |
| Model | PXI-6052E |
| Channels | 16 single-ended or 8 differential (software selectable) |
| Resolution | 16-Bit |
| Maximum Sampling Rate | 333 kS/s |
| Analog Outputs | 2 |
| Triggering | Analog/Digital |
| Digital I/O Lines | 8 |
| Analog Input Signal Ranges | 15 |
| Counters/Timers | 2 24-bit |
| Input Range (20 V) | ±10 V (bipolar) |
| Input Range (100 mV) | ±50 mV (bipolar), 0 to 100 mV (unipolar) |
| Transfer Characteristics | ±1.5 (typical), ±3 (maximum) LSB |
| Frequency Scaler | 1 |
| Trigger Lines
Question 1: What are the part numbers for PXI-6052E? Answer 1: 777962-01, 186408E-01 Question 2: How many SE/ diff channels does PXI-6052E have? Question 3: What is the max sampling rate of the PXI-6052E? Question 4: How many DIO lines does the PXI-6052E include? Question 5: What input ranges can the PXI-6052E handle? |