img

186408F-01

The PXI-6052E DAQ features 16-bit resolution, 333 kS/s sampling, 16 channels, and multiple input/output options.

In Stock | Ships Today

img

    Description

    “`html

    The product with Part Number 777962-01, 186408E-01 falls under the Category of PXI Multifunction DAQ and is identified as Model PXI-6052E. This device is equipped with 16 single-ended or 8 differential channels, which are software selectable, offering versatility in connection options.

    It boasts a 16-Bit resolution for precise data acquisition and can handle a Maximum Sampling Rate of up to 333 kS/s, ensuring efficient data capture. The unit provides 2 Analog Outputs and 8 Digital I/O Lines, allowing for a broad range of signal interfacing and control tasks.

    With an extensive capability to handle 15 Analog Input Signal Ranges, it offers flexibility in accommodating various signal types. The device includes 2 x 24-bit Counters/Timers and a Frequency Scaler with 4 bits resolution, enhancing its functionality in complex measurement tasks.

    It also features 6 Trigger Lines, including 1 star trigger, which facilitates precise timing and synchronization with other devices in a test system. The PXI-6052E is equipped with 3 DMA Channels, enabling fast and efficient data transfer.

    The Input Voltage Range for Bipolar signals is ±10 V at a 20 V range and ±50 mV at a 100 mV range, while for Unipolar signals, it is 0 to 100 mV. This wide range of input voltage capabilities ensures the device’s adaptability to various sensor outputs and signal levels.

    In summary, the PXI-6052E is a highly capable and versatile multifunction DAQ device, suitable for a wide range of measurement, control, and test applications, making it an essential tool for engineers and technicians in various fields.

    “`

    Question 1: What is the maximum sampling rate of the PXI-6052E?
    Answer 1: 333 kS/s

    Question 2: How many single-ended channels does the PXI-6052E have?
    Answer 2: 16 single-ended channels

    Question 3: What is the input voltage range for bipolar signals on the PXI-6052E?
    Answer 3: ±10 V at a 20 V range

    Question 4: How many analog outputs does the PXI-6052E offer?
    Answer 4: 2 Analog Outputs

    Question 5: Does the PXI-6052E include a frequency scaler?
    Answer 5: Yes, with 4 bits resolution

    Specification Detail
    Part Number 777962-01, 186408E-01
    Category PXI Multifunction DAQ
    Model PXI-6052E
    Channels 16 single-ended or 8 differential (software selectable)
    Resolution 16-Bit
    Maximum Sampling Rate 333 kS/s
    Analog Outputs 2
    Digital I/O Lines 8
    Analog Input Signal Ranges 15
    Counters/Timers 2 x 24-bit
    Frequency Scaler 1 (4 bits resolution)
    Trigger Lines 6 (including 1 star trigger)
    DMA Channels 3
    Input Voltage Range (Bipolar) ±10 V at 20 V range; ±50 mV at 100 mV range
    Input Voltage Range (Unipolar) 0 to 100 mV
    Transferring Characteristics