Description
The PXI Multifunction DAQ device, identified by part number 191332F-04L (779112-01), is a high-performance, versatile piece of equipment designed for a wide range of data acquisition applications. This specific model, the PXI-6220, is renowned for its robust functionality and reliability in various testing and measurement scenarios.
The NI PXI-6220 offers an impressive array of features including 16 single-ended (SE) or 8 differential (DIFF) analog input (AI) channels, which are capable of handling input ranges from ±10 V to ±0.2 V. This flexibility in input range allows for precise measurement and monitoring of a wide variety of signals.
In addition to its analog capabilities, this device boasts 24 digital I/O lines, with 8 hardware-timed lines capable of speeds up to 1 MHz, providing users with the ability to perform complex digital operations and signal processing. Furthermore, it includes two 32-bit, 80 MHz counter/timers, enhancing its utility in applications requiring precise timing and control.
Connectivity is facilitated through a 68-pin female VHDCI connector, ensuring easy integration with other devices and systems. The PXI-6220 is supported by a comprehensive suite of software, including NI-DAQmx, NI-DAQmx Base, NI Measurement Hardware DDK, and compatibility with LabVIEW (7.x or later), LabWindows/CVI (7.x or later), Measurement Studio (7.x or later), LabVIEW SignalExpress (1.x or later), Visual Studio .NET, ANSI C/C++, and Visual Basic 6.0. This extensive software support ensures that users can easily develop custom applications and interfaces for their specific needs.
This device has been announced by National Instruments and is available for purchase and repairs through Apex Waves. Its mature status indicates a proven track record of performance and reliability in demanding applications, making it a valuable asset for any data acquisition system.
| Feature | Description |
|---|---|
| Part Number | 191332F-04L (779112-01) |
| Category | PXI Multifunction DAQ |
| Model | PXI-6220 |
| Description | NI PXI-6220 (16 AI, 24 DIO) |
| Analog Inputs | 16 SE/8 DIFF AI channels |
| Input Range | ±10 V to ±0.2 V |
| Digital I/O Lines | 24, 245 V logic (8 hardware-timed up to 1 MHz) |
| Counter/Timers | Two 32-bit, 80 MHz |
| Connector | One 68-pin female VHDCI |
| Software Support | NI-DAQmx, NI-DAQmx Base, NI Measurement Hardware DDK, LabVIEW (7.x or later), LabWindows/CVI (7.x or later), Measurement Studio (7.x or later), LabVIEW SignalExpress (1.x or later), Visual Studio .NET, ANSI C/C++, Visual Basic 6.0 |
| Mature Status | Announced by National Instruments, available for purchase and repairs by Apex Waves |
Question 1: What is the input range of the NI PXI-6220?
Answer 1: ±10 V to ±0.2 V
Question 2: How many AI channels does the PXI-6220 have?
Answer 2: 16 SE or 8 DIFF
Question 3: What type of connector does the PXI-6220 use?
Answer 3: 68-pin female VHDCI
Question 4: What software supports the PXI-6220?
Answer 4: LabVIEW, LabWindows/CVI, Measurement Studio