The PXI-6115 is a PXI Multifunction DAQ with 4 differential AI channels, 12-bit resolution, and a max rate of 10 MS/s/channel.

In Stock | Ships Today

img

    Description

    The PXI-6115 is a high-performance PXI Multifunction Data Acquisition (DAQ) device with the part number 187227R-01. This model is designed to meet a variety of system requirements with its comprehensive features set. Other part numbers associated with the PXI-6115 include 187227K-01, 187227H-01, 187227R-03, 778194-01, and 778204-01, indicating the availability of multiple versions to suit specific needs.

    Equipped with 4 differential analog input channels, the PXI-6115 offers a 12-bit resolution for precise data acquisition. It is capable of achieving a maximum sample rate of 10 MS/s per channel, ensuring high-speed performance for demanding applications. In addition to its analog input capabilities, this device also features 2 analog output channels and 8 digital I/O lines, providing versatility in interfacing with various sensors and actuators.

    The analog input FIFO buffer size varies depending on the specific model, with options of 16 MS for the 778194-01 and 32 MS for the 778204-01, allowing for efficient data handling and storage. The input range of the PXI-6115 is quite broad, ranging from 0.2 to 42 V, accommodating a wide array of signal types.

    In terms of signal conditioning, the PXI-6115 incorporates 3-pole Bessel filters for both 50 kHz and 500 kHz, ensuring clean and reliable signal acquisition. Additionally, it features two 24-bit counter/timers, enhancing its functionality in measurement and timing applications.

    For connectivity, the device uses SMB connectors and a 68-pin male SCSI I/O connector, facilitating easy and secure connections to other modules and systems. It is recommended to allow a warm-up time of 15 minutes for optimal performance, ensuring that the PXI-6115 operates accurately and reliably in a variety of conditions.

    Question 1: What is the max sample rate per channel on the PXI-6115?
    Answer 1: 10 MS/s per channel.

    Question 2: How many AI channels does the PXI-6115 have?
    Answer 2: 4 differential AI channels.

    Question 3: What resolution does the PXI-6115 offer?
    Answer 3: 12-bit resolution.

    Question 4: What type of connectors does the PXI-6115 use?
    Answer 4: SMB and 68-pin male SCSI I/O connectors.

    Question 5: What are the FIFO buffer sizes for models 778194-01 and 778204-01?
    Answer 5: 16 MS for 778194-01 and 32 MS for 778204-01.

    Specification Detail
    Part Number 187227R-01
    Category PXI Multifunction DAQ
    Model PXI-6115
    Other Part Numbers 187227K-01, 187227H-01, 187227R-03, 778194-01, 778204-01
    Analog Input Channels 4 differential
    Resolution 12 bit
    Maximum Sample Rate 10 MS/s/channel
    Analog Output Channels 2
    Digital I/O Lines 8
    Analog Input FIFO Buffer Size 16 MS (778194-01), 32 MS (778204-01)
    Input Range 0.2 to 42 V
    Analog Filters 3-pole Bessel (50 kHz and 500 kHz)
    Counter/Timers Two 24-bit
    Connectivity SMB connectors, 68-pin male SCSI I/O connector
    Recommended Warm-Up Time 15 minutes