Description
The PXI-6224 is a multifunction DAQ device belonging to the PXI category, with a part number of 191332E-02L (779114-01). This device is designed to offer a wide range of data acquisition capabilities, making it a versatile choice for various applications.
It features 32 Analog Inputs, which can be configured as 16 differential or 32 single-ended channels, depending on the user’s requirements. Additionally, it comes equipped with 48 Digital I/O channels, providing ample connectivity for digital signals. The PXI-6224 is capable of supporting 2 general-purpose counters/timers and includes 1 frequency generator channel, enhancing its utility in complex data acquisition and control scenarios.
With a 16-bit resolution, the device ensures high-precision measurements. It is capable of a maximum sample rate of 250 kS/s, suitable for capturing fast transient signals. The timing resolution of 50 ns allows for precise timing and synchronization of events.
The PXI-6224 utilizes an SCC (Signal Conditioning System), capable of a maximum conditioning rate of 1.25 MHz, facilitating the accurate processing of signals. It is compatible with NIDAQmx driver software, ensuring easy integration with a wide range of applications and software environments.
For optimal performance, a recommended warm-up time of 15 minutes is advised. The device requires calibration at an interval of either annually or every two years, ensuring sustained accuracy and reliability over time. Weighing just 5.9 oz, it is lightweight and easily integrated into existing setups without adding significant bulk.
The PXI-6224 operates within a temperature range suitable for various environments, maintaining its performance across a wide spectrum of operating conditions. This makes it an ideal choice for professionals seeking a reliable and high-performance data acquisition solution.
| Specification | Details |
|---|---|
| Part Number | 191332E-02L (779114-01) |
| Category | PXI Multifunction DAQ |
| Model | PXI-6224 |
| Description | 32 Analog Inputs, 48 Digital I/O |
| Analog Input Channels | 16 differential or 32 single ended |
| Counters/Timers | 2 general-purpose |
| Frequency Generator Channels | 1 |
| Resolution | 16 bits |
| Maximum Sample Rate | 250 kS/s |
| Timing Resolution | 50 ns |
| Signal Conditioning System | SCC |
| Maximum Conditioning Rate | 1.25 MHz |
| Driver Software | NIDAQmx |
| Recommended Warm-Up Time | 15 minutes |
| Calibration Interval | Annually or every two years |
| Weight | 5.9 oz |
| Operating Temperature Range |