img

191501H-11L

The PXI-6289 is an 18-bit PXI Multifunction DAQ with 32 AI, 4 AO, 48 DIO, two 32-bit counters, and a max sample rate of 625 kS/s.

In Stock | Ships Today

img

    Description

    The PXI-6289 is a high-performance PXI Multifunction DAQ designed for a wide range of applications. This model boasts a variety of features that make it a versatile choice for engineers and scientists alike.

    It comes equipped with 4 Analog Outputs (AO), allowing for precise control over external devices. Additionally, the device offers a substantial number of Digital I/O (DIO) ports, totaling 48, which is ideal for interfacing with various digital devices.

    For input, the PXI-6289 provides 32 Analog Inputs (AI), which can be configured as 16 differential or 32 single-ended channels, giving users flexibility in connecting sensors and signals. The resolution of these inputs is 18-Bit, ensuring high precision in measurements.

    The device is capable of achieving a Maximum Sample Rate of 625 kS/s, with a reduced rate of 500 kS/s in Multichannel Mode, facilitating rapid data acquisition across multiple channels simultaneously.

    In terms of timing, it offers a Timing Resolution of 50 ns and a Timing Accuracy of 50 ppm, which are critical for synchronized operations and precise timing measurements. The PXI-6289 also includes Two 32-bit Counter/Timers, enhancing its capability for complex timing, counting, and pulse generation tasks.

    Triggering options include both Analog and Digital triggers, allowing for flexible integration into automated setups and experiments. This model is available with two part numbers, 779639-01 for the PXI hybrid bus connector and 779123-01 for the PXI bus connector, accommodating different system configurations.

    Before use, a Warm-up Time of 15 minutes is recommended to ensure accurate operation. To maintain its precision, a Calibration Period of At least once in 2 years

    Question 1: What is the maximum sample rate of the PXI-6289?
    Answer 1: 625 kS/s

    Question 2: How many analog inputs does the PXI-6289 have?
    Answer 2: 32 AI

    Question 3: What is the resolution of the analog inputs on the PXI-6289?
    Answer 3: 18-Bit

    Question 4: How many Digital I/O ports does the PXI-6289 offer?
    Answer 4: 48 DIO

    Question 5: What is the recommended calibration period for the PXI-6289?
    Answer 5: At least once in 2 years

    Specification Detail
    Model PXI-6289
    Category PXI Multifunction DAQ
    Analog Outputs (AO) 4 AO
    Digital I/O (DIO) 48 DIO
    Analog Inputs (AI) 32 AI
    Resolution 18-Bit
    Maximum Sample Rate 625 kS/s
    Counter/Timers Two 32-bit
    Triggering Analog and Digital
    Part Numbers 779639-01 (PXI hybrid bus connector), 779123-01 (PXI bus connector)
    Warm-up Time 15 minutes
    Calibration Period At least once in 2 years
    Analog Input Channels 16 differential or 32 single-ended
    Sample Rate (Multichannel Mode) 500 kS/s
    Timing Resolution 50 ns
    Timing Accuracy 50 ppm