img

191325B-03

The NI PXI-6251 is a PXI Multifunction DAQ with various features including 16-bit resolution and compatibility with NI-DAQmx, not supporting NI-DAQ Legacy.

In Stock | Ships Today

img

    Description

    The PXI Multifunction DAQ, model PXI-6251, is identified by part numbers 779631-01, 191325F-13L, and 779117-01. This device is designed specifically for use as SCXI Control of PXI/SCXI Combo Chassis, offering robust solutions for data acquisition tasks.

    It features 8 differential or 16 single-ended analog input channels and 2 analog output channels, providing considerable flexibility for various data acquisition needs. Additionally, the device is equipped with 24 digital I/O channels, enhancing its utility in complex setups.

    The PXI-6251 boasts a 16-bit analog input resolution, ensuring precise data capture. For connectivity, it includes 1 68-pin VHDCI I/O connector, facilitating easy and reliable connection to other devices and sensors.

    It is important to note that this device is not compatible with NI-DAQ Legacy driver software. Instead, it operates with NI-DAQmx driver software, offering a modern and efficient software environment for device operation and data management.

    For optimal performance, a recommended warm-up time of 15 minutes is advised. To maintain accuracy, calibration is required at least once every 2 years. The PXI-6251 is lightweight, weighing just 7.8 oz, and can operate within a temperature range of 0 °C to 55 °C, making it suitable for a variety of environments.

    Feature Description
    Part Number 779631-01, 191325F-13L, 779117-01
    Category PXI Multifunction DAQ
    Model PXI-6251
    Description NI PXI-6251 for use as SCXI Control of PXI/SCXI Combo Chassis
    Analog Input Channels 8 differential or 16 single-ended
    Analog Output Channels 2
    Digital I/O Channels 24
    Analog Input Resolution 16-bit
    Connectivity 1 68-pin VHDCI I/O connector
    Compatibility Not compatible with NI-DAQ Legacy driver software
    Driver Software NI-DAQmx
    Recommended Warm-up Time 15 minutes
    Calibration Period At least once every 2 years
    Weight 7.8 oz
    Operating Temperature Range 0 °C to 55 °C

    Question 1: What is the analog input resolution of PXI-6251?
    Answer 1: 16-bit

    Question 2: How often does the PXI-6251 require calibration?
    Answer 2: At least once every 2 years

    Question 3: What type of driver software is compatible with PXI-6251?
    Answer 3: NI-DAQmx

    Question 4: What is the weight of the PXI-6251 device?
    Answer 4: 7.8 oz

    Question 5: Does the PXI-6251 support differential analog inputs?
    Answer 5: Yes, 8 differential channels