Description
The PXI-6251 comes with a variety of part numbers, including 779631-01, 191325F-13L, and 779117-01. This model is designed with flexibility in mind, featuring 16 single-ended or 8 differential analog inputs, allowing for a wide range of data acquisition possibilities.
Additionally, it is equipped with 24 digital I/O channels and 2 analog outputs, providing ample connectivity for various applications. The analog inputs boast a 16-bit resolution, ensuring precise data capture.
For connectivity, the device uses a 1 68-pin VHDCI I/O connector, making it compatible with high-density, high-speed data acquisition tasks. It works seamlessly with NI-DAQmx compatible software, offering a robust platform for data analysis and processing.
To facilitate easy and reliable connections, a 2 m Shielded SHC68-68-EPM Cable is recommended, alongside the SCB-68 Spring-Screw terminal connector block, for optimal signal integrity and ease of use.
The device requires calibration at least once every 2 years to maintain accuracy and reliability. Additionally, a 15-minute warm-up time is necessary before it reaches operational stability, ensuring precise measurements.
With a modest weight of 7.8 oz, this module is not only powerful but also lightweight, making it an ideal choice for portable or space-constrained applications. It operates within a temperature range of 0 °C to 55 °C, accommodating a variety of environmental conditions.
| Specification | Detail |
|---|---|
| Part Numbers | 779631-01, 191325F-13L, 779117-01 |
| Model | PXI-6251 |
| Analog Inputs | 16 Single-Ended or 8 Differential |
| Digital I/O Channels | 24 |
| Analog Outputs | 2 |
| Analog Input Resolution | 16-bit |
| Connectivity | 1 68-pin VHDCI I/O connector |
| Compatible Software | NI-DAQmx |
| Recommended Cable | 2 m Shielded SHC68-68-EPM Cable |
| Terminal Connector Block | SCB-68 Spring-Screw |
| Calibration Period | At least once every 2 years |
| Warm-up Time | 15 minutes |
| Weight | 7.8 oz |
| Operating Temperature Range | 0 °C to 55 °C |
Question 1: What is the calibration interval for the PXI-6251?
Answer 1: It requires calibration every 2 years.
Question 2: How many analog inputs does the PXI-6251 have?
Answer 2: 16 SE or 8 Diff analog inputs.
Question 3: What is the resolution of the PXI-6251’s analog inputs?
Answer 3: 16-bit resolution.
Question 4: What type of cable is recommended for the PXI-6251?
Answer 4: 2 m Shielded SHC68-68-EPM Cable.
Question 5: What is the operating temperature range of the PXI-6251?
Answer 5: 0 °C to 55 °C.