img

191325B-01L

The PXI-6259 is a multifunction DAQ with 16/32 AI channels, 48 DIO, 4 AO, and features NI-MCal, compatible with LabVIEW and others, requiring annual calibration.

In Stock | Ships Today

img

    Description

    The PXI-6259 is a multifunction Data Acquisition (DAQ) device designed for a wide range of applications. It comes with a variety of part numbers, including 191325B-01L, 779632-01, and 191325F-01L, ensuring flexibility and compatibility for different systems.

    This high-performing DAQ device falls under the category of PXI Multifunction DAQ, which is known for its reliability and high-speed data acquisition capabilities. It boasts an impressive array of 16 differential or 32 single-ended analog input channels, each with a 16-Bit resolution and a maximum sampling rate of 1.25 MS/s. This allows users to capture high-quality data from a variety of sensors and inputs.

    In addition to analog inputs, the PXI-6259 is equipped with 48 digital I/O channels, providing extensive interfacing capabilities with external devices. It also offers 4 analog output channels for generating signals or controlling other equipment.

    The device includes two 32-bit timers/counters and 6 DMA channels, enhancing its performance in applications requiring precise timing and high-throughput data streaming. With seven programmable input ranges per channel, it can accommodate a wide range of signal levels, from small sensors to high-voltage sources. The PXI-6259 also supports quadrature encoder inputs (X1, X2, X4), allowing it to directly interface with rotary encoders for position and motion control applications.

    The maximum operating voltage for analog input ground (AI GND) is ±11 V, and the input impedance is exceptionally high (>10 GΩ in parallel with 100 pF), minimizing the loading effect on measured circuits. This device also features a fine timing resolution of 50 ns, enabling precise control and synchronization of external devices.

    Calibration is an essential aspect of maintaining the accuracy of the PXI-6259, with services available annually or every two years. It incorporates NI-MCal calibration technology, ensuring reliable performance over time. Software compatibility is broad, supporting

    Feature Description
    Part Numbers 191325B-01L, 779632-01, 191325F-01L
    Category PXI Multifunction DAQ
    Model PXI-6259
    Analog Input Channels 16 differential or 32 single-ended, 16-Bit, 1.25 MS/s
    Digital I/O Channels 48
    Analog Output Channels 4
    Timers/Counters Two 32-bit
    DMA Channels 6
    Input Ranges/Channel Seven programmable
    Quadrature Encoder Inputs X1, X2, X4
    Maximum Operating Voltage (AI GND) ±11 V
    Input Impedance >10 GΩ in parallel with 100 pF (AI+ to AI GND) and (AI- to AI GND)
    Timing Resolution 50 ns
    Calibration Technology NI-MCal
    Software Compatibility NI-DAQmx, LabVIEW, LabWindows, Measurement Studio
    Connector 68-pin shielded connector block
    Obsolete Status Announced
    Calibration Available, recommended annually or every two years

    Question 1: How many AI channels does the PXI-6259 have?
    Answer 1: 16 differential or 32 single-ended channels

    Question 2: What is the max AI sampling rate for PXI-6259?
    Answer 2: 1.25 MS/s

    Question 3: Does the PXI-6259 support quadrature encoder inputs?
    Answer 3: Yes, it supports X1, X2, X4 inputs.

    Question 4: What is the AI GND max operating voltage for PXI-6259?
    Answer 4: ±11 V

    Question 5: Is calibration for PXI-6259 required annually?
    Answer 5: Yes, available annually or every two years.