img

191501C-03

The NI PXI-6281 is a multifunction DAQ with 16 AI, 24 DIO, 2 AO, 18-bit resolution, and a 625 kS/s max sample rate.

In Stock | Ships Today

img

    Description

    The NI PXI-6281, with part number 191501C-03 (also known as 779121-01), is a multifunction Data Acquisition (DAQ) device designed for the PXI platform. This device falls under the category of PXI Multifunction DAQ, offering a comprehensive solution for various data acquisition needs.

    The PXI-6281 model provides a total of 16 Analog Input (AI) channels, allowing for the monitoring and recording of multiple analog signals simultaneously. Additionally, it features 2 Analog Output (AO) channels, enabling the generation of analog signals for testing or control purposes. The device also incorporates 24 Digital I/O (DIO) channels, offering versatility for digital signal processing and control.

    With a high resolution of 18 Bits, the PXI-6281 ensures accurate signal representation, capturing the nuances of the measured or generated signals. It supports a Maximum Sample Rate of 625 kS/s, allowing for the rapid acquisition of data to meet the needs of high-speed applications.

    The device operates with NIDAQmx driver software, providing a user-friendly interface and powerful functionalities for data acquisition, analysis, and presentation. Users are recommended to allow a Warm-Up Time of 15 minutes for optimal performance, and it is advised to undergo calibration at least once every 2 years to maintain accuracy and reliability.

    The PXI-6281 is designed to operate within a Temperature Range of 0 °C to 55 °C and can be stored in temperatures ranging from -20 °C to 70 °C. It functions optimally within a Humidity Range of 10% RH to 90% RH, noncondensing, ensuring robust performance in various environmental conditions.

    Compliance with IEC 61010-1, EN 61010-1, UL 61010-1, and CSA

    Question 1: What is the max sample rate of the NI PXI-6281?
    Answer 1: 625 kS/s

    Question 2: How many AI channels does the PXI-6281 have?
    Answer 2: 16 AI channels

    Question 3: What is the resolution of the PXI-6281 DAQ device?
    Answer 3: 18 bits

    Question 4: How often should the PXI-6281 be calibrated?
    Answer 4: Every 2 years

    Question 5: What temperature range can the PXI-6281 operate in?
    Answer 5: 0 °C to 55 °C

    Part Number 191501C-03 (Also known as 779121-01)
    Category PXI Multifunction DAQ
    Model PXI-6281
    Description NI PXI-6281 (16 AI, 24 DIO, 2 AO)
    Analog Input Channels 16
    Analog Output Channels 2
    Digital I/O Channels 24
    Resolution 18 Bits
    Maximum Sample Rate 625 kS/s
    Driver Software NIDAQmx
    Recommended Warm-Up Time 15 minutes
    Calibration Period At least once every 2 years
    Operating Temperature Range 0 °C to 55 °C
    Storage Temperature Range -20 °C to 70 °C
    Humidity Range 10% RH to 90% RH, noncondensing
    Compliance Standards IEC 61010-1, EN 61010-1, UL 61010-1, CSA 61010-1
    Weight 7.9 oz
    Calibration Option