Description
The 191501B-98 (779122-01) part number refers to the PXI-6284 model, a high-performance PXI Multifunction DAQ device designed by National Instruments. This module is specifically engineered for versatile and robust I/O operations, making it an ideal choice for a wide range of data acquisition and control applications.
The PXI-6284 features an impressive array of technical specifications that underscore its capabilities in precision measurement and control. With 32 analog input channels, it provides ample scope for monitoring multiple parameters simultaneously. The data acquisition process is enhanced by an 18-bit resolution, ensuring high fidelity in the captured signals.
One of the device’s noteworthy features is its prescaling ability, which includes 8X and 2X in each counter, facilitating efficient data processing and analysis. Additionally, the module supports duplicate count prevention, further enhancing the accuracy and reliability of its performance.
For developers and engineers, the PXI-6284 offers NI-DAQmx driver compatibility, simplifying integration and software development efforts. Moreover, the device boasts a digital isolation function, providing an extra layer of protection against electrical noise and potential damage from high-voltage spikes.
Prior to operation, a recommended warm-up time of 15 minutes is advised to ensure optimal performance. To maintain its precision, calibration is recommended at least once every 2 years. Physical connectivity options are robust, with 2 68-pin VHDCI I/O connectors, facilitating easy and secure connections to external sensors and actuators.
Despite its advanced features, the PXI-6284 maintains a compact form factor with a weight of just 8.1 oz. It is designed to operate within a temperature range of 0 °C to 55 °C, and can be stored safely between -20 °C to 70 °C, ensuring durability and reliability across various environmental conditions.
| Specification | Detail |
|---|---|
| Part Number | 191501B-98 (779122-01) |
| Category | PXI Multifunction DAQ |
| Model | PXI-6284 |
| Description | National Instruments PXI-6284 PXI Multifunction I/O Module |
| Prescaling | 8X and 2X in each counter |
| Analog Input Channels | 32 |
| Resolution | 18-bit |
| Duplicate Count Prevention | Supported |
| Driver Compatibility | NI-DAQmx |
| Digital Isolation Function | Available |
| Recommended Warm-Up Time | 15 minutes |
| Calibration Frequency | At least once every 2 years |
| Connectors | 2 68-pin VHDCI I/O |
| Weight | 8.1 oz |
| Operating Temperature Range | 0 °C to 55 °C |
| Storage Temperature Range | -20 °C to 70 °C |