Description
The product features a variety of Part Numbers including 778993-01, 778993-02, and 778993-03, each designed to meet specific needs. It offers a 16-Channel configuration, providing ample connectivity for a wide range of applications.
With a Maximum Sampling Rate of 100 MHz, this device is capable of capturing high-speed signals with precision. It utilizes LVDS signaling to ensure robust data transmission and integrity across all channels.
The Onboard Memory per Channel varies depending on the model, with options including 2 Mb for the 778993-01, 16 Mb for the 778993-02, and a substantial 128 Mb for the 778993-03. This flexibility allows users to choose the most appropriate memory size for their specific data storage requirements.
It supports a Maximum Onboard Clock Frequency range from 48 Hz to 100 MHz, enabling precise control over signal timing and synchronization. The device offers multiple Generation Modes, including Single-waveform mode and Scripted mode, providing versatility in signal generation tasks.
Equipped with a comprehensive set of Triggers, including Start Trigger, Pause Trigger, Script Trigger, Advance Trigger, and Reference Trigger, it offers enhanced control over waveform generation and analysis.
The product is compatible with a range of software, including LabVIEW 7.0 or later, Microsoft Visual C/C++ 6.0 or later, and LabWindows™/CVI™ 6.0 or later, ensuring easy integration into existing systems.
It has a weight of 12 oz. and dimensions of 8.5 x 0.8 x 5.1 in. (H x W x D), making it a compact yet powerful solution for a variety of testing and measurement applications.
Despite being Declared Obsolete by National Instruments, this device is still available for purchase and repairs through Apex Waves, ensuring long-term support and availability for users.
| Specification | Detail |
|---|---|
| Part Numbers | 778993-01, 778993-02, 778993-03 |
| Channels | 16-Channel |
| Maximum Sampling Rate | 100 MHz |
| Signaling | LVDS |
| Onboard Memory per Channel | 2 Mb (778993-01), 16 Mb (778993-02), 128 Mb (778993-03) |
| Maximum Onboard Clock Frequency | 48 Hz to 100 MHz |
| Generation Modes | Single-waveform mode, Scripted mode |
| Triggers | Start Trigger, Pause Trigger, Script Trigger, Advance Trigger, Reference Trigger |
| Software Compatibility | LabVIEW 7.0 or later, Microsoft Visual C/C++ 6.0 or later, LabWindows™/CVI™ 6.0 or later |
| Weight | 12 oz. |
| Dimensions (H x W x D) | 8.5 x 0.8 x 5.1 in. |
| Obsolete Status | Declared by National Instruments, available for purchase and repairs by Apex Waves |
Question 1: What is the max sampling rate of the PXI-6561?
Answer 1: 100 MHz
Question 2: What signaling does the PXI-6561 use?
Answer 2: LVDS
Question 3: How many channels does the PXI-6561 have?
Answer 3: 16 channels
Question 4: Is the PXI-6561 compatible with LabVIEW 7.0?
Answer 4: Yes, LabVIEW 7.0+
Question 5: Who provides support for the PXI-6561 after it was declared obsolete?
Answer 5: Apex Waves