Description
95% (non-condensing)
The National Instruments PXI-6608 PXI Counter/Timer Module, with its part number 777937-01, falls under the category of PXI Timing I/O. This module is designed to provide precise timing and I/O operations, making it an essential component for a wide range of applications.
It features eight up/down counters/timers with a resolution of 32 bits, ensuring high precision for your measurements and timing operations. The power requirement for this module ranges from 1 A to 2.5 A, making it compatible with most PXI systems without demanding excessive power.
Moreover, the PXI-6608 is equipped with Schmitt Triggers that have a hysteresis of 300 mV, which aids in the reliable detection of input signals even in noisy environments. Its ability to measure and source frequencies up to 80 MHz each makes it highly versatile for a range of applications.
The module also boasts an input impedance range of 25 kΩ to 500 kΩ and an output impedance of 75 Ω, ensuring compatibility with a wide variety of sensors and devices. With a warm-up time of only five minutes, the PXI-6608 can quickly reach operational stability.
Designed to operate within a temperature range of 0 °C to 55 °C and to be stored in temperatures ranging from –20 °C to 70 °C, this module is built to withstand challenging environmental conditions. Additionally, it can operate in humidity levels from 0% to 90% (non-condensing) and be stored in humidity levels from 5% to 95% (non-condensing), ensuring reliability in various climates.
In summary, the National Instruments PXI-6608 module is a powerful and reliable solution for advanced timing and I/O operations, making it an invaluable tool for engineers and researchers alike.
| Specification | Details |
|---|---|
| Part Number | 777937-01 |
| Category | PXI Timing I/O |
| Model | PXI-6608 |
| Description | National Instruments PXI-6608 PXI Counter/Timer Module |
| Counters/Timers | Eight up/down, 32 bits resolution |
| Power Required | 1 A to 2.5 A |
| Schmitt Triggers Hysteresis | 300 mV |
| Measure and Source Frequencies | 80 MHz each |
| Input Impedance | 25 kΩ to 500 kΩ |
| Output Impedance | 75 Ω |
| Warm-up Time | Five minutes |
| Operating Temperature Range | 0 °C to 55 °C |
| Storage Temperature Range | –20 °C to 70 °C |
| Operating Humidity Range | 0% to 90% (non-condensing) |
| Storage Humidity Range | 5% to
Question 1: What is the part number of the PXI-6608 module? Question 2: How many counters/timers does the PXI-6608 have? Question 3: What is the power requirement for the PXI-6608? Question 4: What is the operational temperature range of the PXI-6608? Question 5: What type of triggers does the PXI-6608 feature? |