Description
The National Instruments FP-DI-300 Digital Input Module, with part number 777518-300, is a specialized component designed for FieldPoint systems that accommodates a wide voltage range of up to 250 V. This module is engineered for seamless installation, as it can be integrated into a powered terminal base without affecting the operation of other modules in the system.
Power is conveniently supplied to the FP-DI-300 directly from the terminal base, eliminating the need for separate power arrangements. The module boasts eight input channels, each with its own green status indicator, to effectively monitor digital signals. Furthermore, it offers the flexibility of connecting an external power supply to energize field devices.
The FP-DI-300 is compatible with sourcing output devices and features sinking inputs—meaning that it sinks current from the Vin terminal to the common (COM) terminal—enhancing its versatility in various applications. The module’s design includes optical isolators with current-limiting resistors for each input channel, which are referenced to Vin, ensuring reliable and safe operation.
Operational readiness is clearly indicated by the illumination of the READY indicator, which, along with the green POWER indicator, signifies that the module is functioning correctly and is in its normal operating mode. These indicators provide immediate visual feedback on the status of the module and its channels.
Specification | Details |
---|---|
Product Name | National Instruments FP-DI-300 Digital Input Module |
Part Number | 777518-300 |
Module Type | Digital Input Module for FieldPoint |
Voltage Range | Up to 250 V |
Installation | Can be installed onto a powered terminal base without disrupting other modules |
Power Supply | From terminal base |
Input Channels | 8 |
External Power Supply | Connections for powering field devices |
Input Compatibility | Sourcing output devices |
Input Type | Sinking inputs |
Input Reference | Vin referenced to COM (common) |
Channel Indicators | Each channel has a green status indicator |
Ready Indicator | READY indicator lights up in normal operating mode |
Other Indicators | Green POWER and READY indicators |
Question 1: What is the maximum voltage that the National Instruments FP-DI-300 Digital Input Module can accommodate, and how does the module indicate operational readiness to the user?
Answer 1: The National Instruments FP-DI-300 Digital Input Module can accommodate a maximum voltage of up to 250 V, and it indicates operational readiness to the user through the illumination of the READY indicator, along with a green POWER indicator.
Question 2: What are the features and benefits of integrating the National Instruments FP-DI-300 Digital Input Module into FieldPoint systems?
Answer 2: The National Instruments FP-DI-300 Digital Input Module, designed for FieldPoint systems, features eight input channels with green status indicators for monitoring digital signals, compatibility with sourcing output devices and sinking inputs, optical isolators with current-limiting resistors per channel, and direct power supply from the terminal base. Operational readiness is indicated by the illumination of the READY and POWER indicators, which confirm correct functioning and normal operating mode.
Question 3: How does the National Instruments FP-DI-300 Digital Input Module indicate operational readiness and ensure safe operation in FieldPoint systems?
Answer 3: The National Instruments FP-DI-300 Digital Input Module indicates operational readiness through the illumination of the READY indicator, and it ensures safe operation in FieldPoint systems by incorporating optical isolators with current-limiting resistors for each input channel, which are referenced to Vin, along with a green POWER indicator for visual feedback on the module’s status.
Question 4: What are the key features and indication methods of the National Instruments FP-DI-300 Digital Input Module used in FieldPoint systems?
Answer 4: The National Instruments FP-DI-300 Digital Input Module, integrated into FieldPoint systems, offers features such as handling a wide voltage range up to 250 V, simple installation without disrupting other modules, power supplied directly from the terminal base, eight input channels with green status indicators, compatibility with sourcing output devices, sinking inputs for current sinking from the Vin to COM terminal, and optical isolators with current-limiting resistors for safety. Its benefits include eliminating the need for separate power arrangements, the ability
Question 5: What are the key features of the National Instruments FP-DI-300 Digital Input Module that enhance its compatibility and safety for various applications in FieldPoint systems?
Answer 5: The National Instruments FP-DI-300 Digital Input Module enhances compatibility and safety for various FieldPoint system applications through its ability to accommodate a wide voltage range of up to 250 V, integration without affecting other modules, power supply directly from the terminal base, eight input channels with individual green status indicators, compatibility with sourcing output devices, sinking inputs configuration, optical isolators with current-limiting resistors for each input channel, and clear operational readiness indicators for module status monitoring.