The National Instruments GPIB-VXI GPIB Interface for VXIbus is designed to bridge the VXIbus with the GPIB bus and comes pre-configured as the system resource manager with features like transparent protocol conversion, self-test, initialization functions,
The National Instruments GPIB-VXI GPIB Interface for VXIbus is a specialized interface that ensures seamless linkage between the VXIbus system and the IEEE-488 (GPIB) bus, promoting transparent communication of their respective protocols and signals. It is inherently designed to function as the system resource manager, but this capability can be disabled if another resource manager is preferred.
With its inherent compliance with VXIbus specifications, the GPIB-VXI interface provides essential services such as self-test, startup configuration, and initialization, in addition to handling Slot 0-related services that are pivotal for smooth operation. This interface is equipped with three programmable VXIbus interrupt handlers and an expansive 4 MB of dual-ported memory, enhancing its operational capabilities.
Furthermore, the interface supports the execution of Code Instruments, which are specialized software modules, thus extending its utility. It boasts an array of connectivity options with five connectors including a Serial port, Trigger input and output, a GPIB interface, and an External CLK10 I/O, ensuring versatile integration with various devices. The configurable reset pushbutton adds an extra layer of control, allowing users to reset the backplane, the GPIB-VXI, or both according to their needs.
Feature
Description
Product
National Instruments GPIB-VXI GPIB Interface for VXIbus
Interface
GPIB Interface designed for VXIbus
Compatibility
Links VXIbus and IEEE-488 (GPIB) bus
Functionality
Transparent conversing of GPIB protocols and signals to VXIbus protocols and signals
System Resource Manager
Pre-configured to act as the system resource manager
Self-Test and Initialization
Offers the VXIbus self-test, startup configuration, and initialization functions
Slot 0 Services
Performs Slot 0-related services; can be disabled for use with another RM
Compliance
Fully complies with VXIbus specifications
Interrupt Handlers
Three programmable VXIbus interrupt handlers
Memory
4 MB of dual-ported memory
Code Instruments
Can execute software modules called Code Instruments
Connectors
Five connectors: Serial port, Trigger input, Trigger output, GPIB interface, and External CLK10 I/O
Reset Pushbutton
Configurable to reset the backplane, GPIB-VXI, or both
Question 1: What are the capabilities and features of the National Instruments GPIB-VXI GPIB Interface for VXIbus, and how do they enhance its integration and operational performance within a system? Answer 1: The National Instruments GPIB-VXI interface facilitates the connection between VXIbus systems and the IEEE-488 (GPIB) bus by ensuring seamless communication of protocols and signals, and it provides enhanced functionality in a VXIbus setup through services such as self-test, startup configuration, initialization, Slot 0 service handling, three programmable VXIbus interrupt handlers, 4 MB of dual-ported memory, support for Code Instruments, multiple connectivity options, and a configurable reset pushbutton for versatile
Question 2: What is the function of the configurable reset pushbutton on the National Instruments GPIB-VXI GPIB Interface for VXIbus? Answer 2: The National Instruments GPIB-VXI GPIB Interface for VXIbus ensures effective communication between the VXIbus system and the IEEE-488 bus by functioning as the system resource manager, managing self-test, startup configuration, initialization, handling Slot 0 services, providing three programmable VXIbus interrupt handlers, offering an expansive 4 MB of dual-ported memory, supporting the execution of Code Instruments, and featuring a variety of connectivity options including a serial port, trigger input and output, a GPI
Question 3: What are the functionalities and connectivity features of the National Instruments GPIB-VXI GPIB Interface for VXIbus, and how does it accommodate different users’ needs through its design and capabilities? Answer 3: The configurable reset pushbutton on the National Instruments GPIB-VXI GPIB Interface for VXIbus allows users to selectively reset either the backplane, the GPIB-VXI interface, or both, according to their specific requirements.
Question 4: What functions does the National Instruments GPIB-VXI GPIB Interface for VXIbus perform to ensure effective communication between the VXIbus system and the IEEE-488 bus? Answer 4: The National Instruments GPIB-VXI GPIB Interface for VXIbus is capable of seamless integration with VXIbus and GPIB systems, serving as a system resource manager with optional disablement, and it offers critical services such as self-test, startup configuration, and initialization, as well as managing Slot 0 services. Its operational performance is enhanced by three programmable VXIbus interrupt handlers, 4 MB of dual-ported memory, support for the execution of Code Instruments, and multiple connectivity options
Question 5: How does the National Instruments GPIB-VXI interface facilitate the connection between VXIbus systems and the IEEE-488 (GPIB) bus, and what capabilities does this interface provide to enhance its functionality in a VXIbus setup? Answer 5: The National Instruments GPIB-VXI GPIB Interface for VXIbus functions as a system resource manager (with the option to disable this feature), facilitates communication between VXIbus and GPIB protocols, and provides critical services like self-test, startup configuration, and slot 0 management; its design includes three programmable VXIbus interrupt handlers, 4 MB of dual-ported memory, and supports Code Instruments execution, while its connectivity features encompass five connectors—Serial port, Trigger input/output, GPI