Description
The product with the part number 780587-69 falls under the category of PXI Switches and is identified by the model PXIe-2569. This specific model is a 100-Channel Relay Module, designed to provide versatile switching capabilities in a PXI form factor. The relay configuration is Single-Pole Single-Throw (SPST), which is standard for applications requiring simple on/off control signals.
One of the key features of this module is its minimum pulse width for input triggers, which is 150 nanoseconds. This allows for rapid response to control signals. Additionally, it offers a programmable output trigger pulse width ranging from 1 microsecond to 62 microseconds, providing flexibility in timing for various applications.
The module also boasts a step scan capability, with a built-in list capacity of 32,000 steps. This feature is invaluable for applications that require scanning through a sequence of steps or states. When it comes to handling voltage, the module can switch up to 100 volts both channel-to-channel and channel-to-ground, which is classified under Measurement Category 1. It also has an impulse voltage withstand of 800 volts, ensuring durability under high voltage transients.
Additionally, the module is designed with protection against high voltage transients, ensuring the safety and longevity of the module under harsh conditions. The minimum switch load is specified as 20 mV or 10 mA, catering to low-power applications. At the beginning of the relay’s lifespan, the initial DC path resistance is less than 0.55 ohms, which increases to 1 ohm at the end of the relay’s life. Lastly, it supports a typical bandwidth of >= 20 MHz, making it suitable for a wide range of applications.
| Specification | Detail |
|---|---|
| Part Number | 780587-69 |
| Category | PXI Switches |
| Model | PXIe-2569 |
| Type | 100-Channel Relay Module |
| Relay Configuration | Single-Pole Single-Throw |
| Minimum Pulse Width (Input Triggers) | 150 nanoseconds |
| Programmable Output Trigger Pulse Width | 1 microsecond to 62 microseconds |
| Step Scan Capability | Yes, with a built-in list of 32,000 |
| Maximum Switching Voltage | 100 volts (Channel-to-Channel and Channel-to-Ground) |
| Measurement Category | 1 |
| Impulse Voltage Withstand | 800 volts |
| Protection Against High Voltage Transients | Yes |
| Minimum Switch Load | 20 mV or 10 mA |
| Initial DC Path Resistance | < 0.55 ohms |
| DC Path Resistance at End of Relay Life | 1 ohm |
| Typical Bandwidth | >= 20 MHz |
Question 1: What is the part number for the PXIe-2569?
Answer 1: 780587-69
Question 2: How many channels does the PXIe-2569 have?
Answer 2: 100 channels
Question 3: What is the minimum pulse width of the PXIe-2569?
Answer 3: 150 nanoseconds
Question 4: What is the maximum voltage the PXIe-2569 can handle?
Answer 4: 100 volts
Question 5: What is the initial DC path resistance of the PXIe-2569?
Answer 5: <0.55 ohms