Description
The Part Number 780587-69 references a specific model of PXI Switches, known as the PXIe-2569. This model is categorized as a 100-Channel Relay Module, designed for applications requiring a high number of channels within a compact form factor. The relay configuration for this module is Single-Pole Single-Throw (SPST), which is a common configuration used for simple on/off switching tasks.
One of the key specifications of the PXIe-2569 is its ability to handle Minimum Pulse Width (Input Triggers) as short as 150 nanoseconds, allowing for rapid signal changes. Additionally, it supports Output Triggers Pulse Width Range from 1 microsecond to 62 microseconds, providing flexibility in timing for various applications. The module also features Step Scan Capability, with a built-in step scan list of 32,000, enhancing its versatility in automated test environments.
When it comes to voltage handling, the PXIe-2569 can manage a Maximum Switching Voltage (Channel-to-Channel, Channel-to-Ground) of 100 volts, and it is rated for a Measurement Category of 1. It is designed to withstand Impulse Voltage up to 800 volts, indicating a robust protection against high voltage transients. This protection is further ensured by its capability to safeguard against High Voltage Transients.
The module’s performance is also characterized by its Minimum Switch Load requirements of 20 mV or 10 mA, making it suitable for low-power applications. The Initial DC Path Resistance is less than 0.55 ohms, which slightly increases to 1 ohm at the end of the product’s life. This gradual change in resistance ensures a reliable performance throughout its lifespan.
| Specification | Detail |
|---|---|
| Part Number | 780587-69 |
| Category | PXI Switches |
| Model | PXIe-2569 |
| Type | 100-Channel Relay Module |
| Relay Configuration | Single-Pole Single-Throw |
| Minimum Pulse Width (Input Triggers) | 150 nanoseconds |
| Output Triggers Pulse Width Range | 1 microsecond to 62 microseconds |
| Step Scan Capability | Yes (Built-in step scan list of 32,000) |
| Maximum Switching Voltage (Channel-to-Channel, Channel-to-Ground) | 100 volts |
| Measurement Category | 1 |
| Impulse Voltage Withstand | 800 volts |
| Protection against High Voltage Transients | Yes |
| Minimum Switch Load | 20 mV or 10 mA |
| Initial DC Path Resistance | < 0.55 ohms |
| DC Path Resistance at End of Life | 1 ohm |
| Typical Bandwidth
Question 1: What is the part number for the PXIe-2569? Answer 1: The part number is 780587-69. Question 2: What is the minimum pulse width for the PXIe-2569? Question 3: How many channels does the PXIe-2569 support? Question 4: What is the maximum switching voltage of PXIe-2569? Question 5: What is the initial DC path resistance of PXIe-2569? |