The PXIe-4080 (783129-01) is a 6½ digit PXI Multimeter featuring a maximum voltage of ±300 V and a digitizer sample rate of 1.8 MS/s.

In Stock | Ships Today

img

    Description

    The 783129-01 is a state-of-the-art PXI Multimeter categorized under the model PXIe-4080. Boasting a precision of 6½ digits, it is designed to handle a maximum voltage of ±300 V. This device is capable of a digitizer sample rate of up to 1.8 MS/s, ensuring rapid data acquisition and processing.

    The input impedance is finely tuned to 1 MΩ ± 2% in parallel with 150 pF, optimizing the multimeter for a wide range of applications. When dealing with maximum DC voltage components, the device can safely operate with up to 250 V. Its Common Mode Rejection Ratio (CMRR) is greater than 70 dB from DC up to 60 Hz, showcasing its ability to suppress unwanted interference and noise in measurements.

    The PXIe-4080 excels in frequency measurements as well, with a range from 15 Hz to 500 KHz, and it can accurately measure periods ranging from 2 µs to 66.67 ms. For safety and durability, it features robust input protection capable of withstanding up to 300 VDC or ACrms.

    Resolution is another highlight, offering a flexible range of 10 to 23-bit, enabling precise voltage, current, and resistance measurements. Specifically, it can measure up to 300 Vrms for voltage, up to 1 A for current, and resistance measurements can go up to 100 MΩ. The device’s current mode fuse rating is a testament to its safety features, with a rating of T 1 A 400 V, equipped with a time-lag user-replaceable Minimum interrupt rating of 500 A Littelfuse 0477001.MXP.

    In terms of efficiency, the PXIe-4080 requires less than 9 W of power from the PXI Express backplane, ensuring low power consumption. Compatibility is broad, supporting software such as LabVIEW, Lab

    Specification Detail
    Part Number 783129-01
    Category PXI Multimeters
    Model PXIe-4080
    Digits
    Maximum Voltage ±300 V
    Digitizer Sample Rate 1.8 MS/s
    Input Impedance 1 MΩ ± 2% in parallel with 150 pF
    Maximum DC Voltage Component 250 V
    CMRR >70 dB (DC to 60 Hz)
    Frequency Range 15 Hz to 500 KHz
    Period Measurement Range 2 µs to 66.67 ms
    Input Protection 300 VDC or ACrms
    Resolution 10 to 23-bit flexible
    Voltage Measurements Up to 300 Vrms
    Current Measurements Up to 1 A
    Resistance Measurements Up to 100 MΩ
    Current Mode Fuse Rating T 1 A 400 V, time-lag user-replaceable Minimum interrupt rating: 500 A Littelfuse 0477001.MXP
    Power Consumption Less than 9 W from PXI Express backplane
    Software Compatibility LabVIEW, LabWindows/CVI, ANSI C, Visual Basic
    Amb

    Question 1: What is the max voltage for the PXIe-4080?
    Answer 1: ±300 V

    Question 2: What digitizer sample rate does PXIe-4080 offer?
    Answer 2: 1.8 MS/s

    Question 3: What’s the input impedance of the PXIe-4080?
    Answer 3: 1 MΩ ± 2% in parallel with 150 pF

    Question 4: How much power does the PXIe-4080 consume?
    Answer 4: Less than 9 W

    Question 5: What’s the PXIe-4080’s max DC voltage component?
    Answer 5: 250 V