Description
The Part Number of this PXI Multimeter is 783129-01, classified under the Category of PXI Multimeters. The model for this specific multimeter is identified as PXIe-4080, which boasts a precise measurement capability with its Digits count of 6½.
This device supports a wide Voltage Range of ±300 V, making it versatile for various electrical measurement tasks. Coupled with a Maximum Sample Rate of 1.8 MS/s, it ensures rapid data acquisition for efficient testing processes. The Input Impedance is meticulously designed to be 1 MΩ ± 2% in parallel with 150 pF, optimizing measurement accuracy and reliability.
It can handle a Maximum DC Voltage Component of up to 250 V. Additionally, its CMRR (Common Mode Rejection Ratio) is greater than 70 dB from DC to 60 Hz, which indicates its exceptional ability to reject interference from common mode signals. The multimeter covers a broad Frequency Range from 15 Hz to 500 KHz, making it suitable for a wide spectrum of applications.
The Period Measurement Range it supports spans from 2 µs to 66.67 ms, demonstrating its capability in capturing a wide range of signal periods. With an Input Protection rating of 300 VDC or ACrms, it ensures durability and safety during operation. The Resolution of this multimeter is highly adaptable, ranging from 10 to 23-bit flexible, allowing for precision in measurements.
Furthermore, the Current Mode Fuse Rating is specified as T 1 A 400 V, time-lag user-replaceable Minimum interrupt rating: 500 A Littelfuse 0477001.MXP, which provides reliable protection against overcurrent conditions. Lastly
| Specification | Detail |
|---|---|
| Part Number | 783129-01 |
| Category | PXI Multimeters |
| Model | PXIe-4080 |
| Digits | 6½ |
| Voltage Range | ±300 V |
| Maximum Sample Rate | 1.8 MS/s |
| Input Impedance | 1 MΩ ± 2% in parallel with 150 pF |
| Maximum DC Voltage Component | 250 V |
| CMRR | >70 dB (DC to 60 Hz) |
| Frequency Range | 15 Hz to 500 KHz |
| Period Measurement Range | 2 µs to 66.67 ms |
| Input Protection | 300 VDC or ACrms |
| Resolution | 10 to 23-bit flexible |
| Current Mode Fuse Rating | T 1 A 400 V, time-lag user-replaceable Minimum interrupt rating: 500 A Littelfuse 0477001.MXP |
| Power Consumption | Less than 9 W from PXI Express backplane