The product features part numbers 783130-01 and 154888C-02L, falling under the category of PXI Multimeters. The model PXIe-4081 is equipped with a 7½-Digit resolution, ensuring precise and accurate measurements. It supports a voltage measurement range of up to ±1000 V, making it suitable for a wide range of applications.
Furthermore, the current measurement capability ranges from ±1 µA to ±3 A, accommodating various levels of current testing. The isolated digitizer sample rate varies from 10 S/s to 1.8 MS/s, allowing for flexible data acquisition speeds. With an input impedance of 10 MΩ ± 2% in parallel with 90 pF, the device ensures reliable measurements.
The maximum DC voltage component that can be measured is 400 V, and the frequency range spans from 15 Hz to 500 KHz, making the device versatile in its applications. The period measurement range is from 2 µs to 66.67 ms, and the ADC linearity is up to 0.5 ppm of reading + 0.5 ppm, highlighting the instrument’s precision.
It requires a warm-up time of 60 minutes for optimal performance and has a recommended calibration period of once every 2 years to maintain accuracy. The input protection is rated at 1000 VDC or Vpk, ensuring the safety of the device during operation. Additionally, the current mode fuse rating is T 3.5 A 1000 V, with a time-lag minimum interrupt rating of 10 kA Siba 5019906.3,5, further enhancing its robustness.
Software compatibility includes the NI-DMM driver, LabVIEW, and LabWindows/CVI, providing flexibility in programming and integration into existing systems. The configuration tool, Measurement & Automation Explorer (MAX), aids in the easy setup and management of the device. This long description encapsulates the technical specifications and capabilities of the PXIe-4081, highlighting its suitability for a wide range of precision measurement tasks.
“`
| Specification | Detail |
|---|---|
| Part Numbers | 783130-01, 154888C-02L |
| Category | PXI Multimeters |
| Model | PXIe-4081 |
| Resolution | 7½-Digit |
| Voltage Measurement Range | ±1000 V |
| Current Measurement Range | ±1 µA to ±3 A |
| Isolated Digitizer Sample Rate | 10 S/s to 1.8 MS/s |
| Input Impedance | 10 MΩ ± 2% in parallel with 90 pF |
| Maximum DC Voltage Component | 400 V |
| Frequency Range | 15 Hz to 500 KHz |
| Period Measurement Range | 2 µs to 66.67 ms |
| ADC Linearity | Up to 0.5 ppm of reading + 0.5 ppm |
| Warm-up Time | 60 minutes |
| Calibration Period | Once every 2 years |
| Input Protection | 1000 VDC or Vpk |
| Current Mode Fuse Rating | T 3.5 A 1000 V, time-lag Minimum interrupt rating: 10 kA Siba 5019906.3,5 |
| Software Compatibility | NI-DMM driver, LabVIEW, LabWindows/CVI |
| Configuration Tool | Measurement & Automation Explorer (MAX) |
| Physical
Question 1: What is the voltage range of the PXIe-4081? Question 2: What current range does the PXIe-4081 support? Question 3: What is the sample rate of the PXIe-4081? Question 4: What is the calibration period for the PXIe-4081? Question 5: What software is compatible with the PXIe-4081? |