The PXIe-4081 is a 7½-digit, isolated digital multimeter with a voltage range up to ±1,000 V and a digitizer sample rate up to 1.8 MS/s.

In Stock | Ships Today

img

    Description

    The PXIe-4081 is a high-performance PXI Multimeter that offers an impressive range of technical specifications suitable for a wide range of measurement and testing applications. The part numbers associated with this model are 783130-01 and 154888C-02L, ensuring that users can identify the exact variant of the device they require.

    This multimeter boasts a high resolution of 7½-Digit, providing precise and accurate readings. It is capable of handling a voltage range of up to ±1,000 V, making it suitable for high-voltage applications. Additionally, the digitizer sample rate goes Up to 1.8 MS/s, allowing for fast data acquisition and processing.

    One of the key features of the PXIe-4081 is its Isolated Digital Multimeter design, offering enhanced safety and reliability by isolating the measurement circuitry. The current range of this device spans from ±1 µA to ±3 A, accommodating a broad spectrum of electrical measurements. Furthermore, it has an input impedance of 10 MΩ ± 2% in parallel with 90 pF, optimizing it for various testing scenarios.

    The maximum DC voltage component that can be measured with this multimeter is 400 V, and it supports a frequency range of 15 Hz to 500 KHz, making it versatile for both low and high-frequency measurements. The period measurement range is from 2 µs to 66.67 ms, providing flexibility in timing analysis.

    Accuracy is a paramount concern, and the PXIe-4081 addresses this with an ADC linearity of Up to 0.5 ppm of reading + 0.5 ppm, ensuring high precision in measurements. To maintain its accuracy, the device requires a warm-up time of 60 minutes and a calibration period of Once every 2 years, helping to keep the multimeter performing at its best over time.

    < Question 1: What is the voltage range of the PXIe-4081?
    Answer 1: Up to ±1,000 V

    Question 2: What is the digitizer sample rate of the PXIe-4081?
    Answer 2: Up to 1.8 MS/s

    Question 3: What is the resolution of the PXIe-4081?
    Answer 3: 7½-Digit

    Question 4: How often does the PXIe-4081 need calibration?
    Answer 4: Once every 2 years

    Question 5: What are the part numbers for the PXIe-4081?
    Answer 5: 783130-01, 154888C-02L

    Specification Detail
    Part Number 783130-01, 154888C-02L
    Category PXI Multimeters
    Model PXIe-4081
    Resolution 7½-Digit
    Voltage Range ±1,000 V
    Digitizer Sample Rate Up to 1.8 MS/s
    Isolation Isolated Digital Multimeter
    Current Range ±1 µA to ±3 A
    Input Impedance 10 MΩ ± 2% in parallel with 90 pF
    Maximum DC Voltage Component 400 V
    Frequency Range 15 Hz to 500 KHz
    Period Measurement Range 2 µs to 66.67 ms
    ADC Linearity Up to 0.5 ppm of reading + 0.5 ppm
    Warm-up Time 60 minutes
    Calibration Period Once every 2 years