200099A-01

This device offers 7½ digit resolution, measures voltage up to ±1000V, current from ±1µA to ±3A, with a sample rate up to 1.8MS/s, and weighs 12 oz.

In Stock | Ships Today

img

    Description

    The device with part numbers 783130-01, 154888C-02L offers a high-resolution measurement capability of 7½ digits, allowing for precise and accurate readings. It is capable of measuring voltage ranges of ±1000 V (DC or AC coupled), providing versatility for various electrical testing requirements. The current measurement capabilities range from ±1 µA to ±3 A, accommodating a wide range of current testing scenarios.

    The sample rate of the device can vary from 10 Samples per second (S/s) to 1.8 Mega Samples per second (MS/s), ensuring flexibility in data acquisition speeds. With an input impedance of 10 MΩ ± 2% in parallel with 90 pF, it is designed to minimize loading effects and maintain signal integrity. The maximum DC voltage component that can be measured is 400 V, providing a substantial range for DC voltage measurements.

    Its frequency measurement capabilities span from 15 Hz to 500 KHz, covering a broad spectrum for various applications. The period measurement range is between 2 µs to 66.67 ms, allowing for the measurement of a wide variety of signal periods. The device’s ADC linearity is up to 0.5 ppm of reading + 0.5 ppm, indicating high precision in analog-to-digital conversion processes.

    For optimal performance, the device requires a warm-up time of 60 minutes and recommends a calibration period once every 2 years to maintain accuracy. It features input protection up to 1000 VDC or Vpk, ensuring the device’s safety during operation. The current mode fuse rating is specified as T 3.5 A 1000 V, time-lag Minimum interrupt rating: 10 kA Siba 5019906.3,5, providing ample protection against overcurrent conditions.

    Software compatibility includes NI-DMM driver software, LabVIEW, and LabWindows/CVI, offering flexibility in programming and automation for various testing scenarios. The device can be configured using the Measurement & Automation Explorer (MAX) Specification Details Part Number 783130-01, 154888C-02L Resolution 7½ digits Voltage Measurement Range ±1000 V (DC or AC coupled) Current Measurement Range ±1 µA to ±3 A Sample Rate 10 S/s to 1.8 MS/s Input Impedance 10 MΩ ± 2% in parallel with 90 pF Maximum DC Voltage Component 400 V Frequency Range 15 Hz to 500 KHz Period Measurement Range 2 µs to 66.67 ms ADC Linearity Up to 0.5 ppm of reading + 0.5 ppm Warm-up Time 60 minutes Calibration Period Once every 2 years Input Protection 1000 VDC or Vpk Current Mode Fuse Rating T 3.5 A 1000 V, time-lag Minimum interrupt rating: 10 kA Siba 5019906.3,5 Software Compatibility NI-DMM driver software, LabVIEW, LabWindows/CVI Configuration Tool Measurement & Automation Explorer (MAX) Physical Dimensions 8.5 x 5.1 x 8.5 in. Weight 12 oz.Question 1: What is the max voltage measurement for the PXIe-4081?
    Answer 1: ±1000 V

    Question 2: What current range does the PXIe-4081 cover?
    Answer 2: ±1 µA to ±3 A

    Question 3: How fast can the PXIe-4081 sample?
    Answer 3: Up to 1.8MS/s

    Question 4: What is the warm-up time for the PXIe-4081?
    Answer 4: 60 minutes

    Question 5: What software is compatible with the PXIe-4081?
    Answer 5: NI-DMM, LabVIEW, LabWindows/CVI