Description
The product comes with part numbers 782857-01 and 782956-01, ensuring you have the exact model for your specific needs. It is designed with a 2-Channel configuration, providing versatility in its application. With a voltage range of up to 60 V and a current range of up to 1 A, it meets a wide variety of power supply requirements.
This device features programmable power, allowing for precise control over power settings. The outputs are isolated, enhancing safety and performance. Additionally, it includes output disconnect functionality as a standard feature, furthering its utility and safety. The presence of a remote sense capability ensures accuracy in power delivery, compensating for voltage drops in the power lines.
Compatibility with software such as LabVIEW, LabWindows/CVI, and Microsoft Visual C/C++ makes it a versatile tool for various development environments. The device is easily configured using the Measurement & Automation Explorer (MAX) tool, simplifying setup and use.
It requires a warm-up time of 30 minutes for optimal performance and recommends a calibration period of at least once every 2 years to maintain accuracy. The power requirement is minimal, needing only 0.5 A from a 3.3 V rail and 0.25 A from a 12 V rail. Additionally, an auxiliary power source input of 45.6 VDC to 50.4 VDC, with a maximum of 3.5 A, supports its operations.
The device delivers an output power of 60 W/channel, totaling 120 W, and features an analog output voltage range from 0 V to 60 V. The auxiliary power input line regulation is specified at a voltage of 1 mV and a current
| Specification | Detail |
|---|---|
| Part Numbers | 782857-01, 782956-01 |
| Channels | 2-Channel |
| Voltage Range | 60 V |
| Current Range | 1 A |
| Programmable Power | Yes |
| Isolated Outputs | Yes |
| Output Disconnect Functionality | Standard |
| Remote Sense | Yes |
| Software Compatibility | LabVIEW, LabWindows/CVI, Microsoft Visual C/C++ |
| Configuration Tool | Measurement & Automation Explorer (MAX) |
| Warm-up Time | 30 minutes |
| Calibration Period | At least once every 2 years |
| Power Requirement | 0.5 A from 3.3 V rail, 0.25 A from 12 V rail |
| Auxiliary Power Source Input | 45.6 VDC to 50.4 VDC, 3.5 A max |
| Output Power | 60 W/channel (Total 120 W) |
| Analog Output Voltage Range | 0 V to 60 V |
| Auxiliary Power Input Line Regulation | Voltage: 1 mV, Current: 0.2 mA |
| Remote Sense Lead Drop | Up to 1 V drop per lead |
| Remote Sense Lead Resistance | Up to 1 Ω per lead |