img

782857-01

The PXIe-4112 is a 2-channel programmable power instrument with a 60V, 1A range, supporting LabVIEW and requiring calibration every 2 years.

In Stock | Ships Today

img

    Description

    “`html

    The PXIe-4112 is a model from the PXI Programmable Power Instruments category, designed to meet the needs of a wide range of power testing and simulation scenarios. This particular model includes part numbers 782857-01 and 782956-01, ensuring a variety of options for specific project requirements.

    Equipped with 2 channels, the PXIe-4112 boasts a voltage range up to 60 V and a current range up to 1 A. The minimum programmable voltage level/limit is set at 0.1 V, while the minimum programmable current level is 0.01 A. This flexibility allows for precise control over the power supplied to the device under test.

    Furthermore, the PXIe-4112 delivers an impressive output power of 60 W/channel, totaling 120 W across both channels. This ensures adequate power for a wide array of testing scenarios. Compatibility with software such as LabVIEW, LabWindows/CVI, and Microsoft Visual C/C++ makes integration into existing systems seamless and straightforward.

    The power requirements for the PXIe-4112 are modest, needing just 0.5 A from the 3.3 V rail, and 0.25 A from the 12 V rail. The auxiliary power source input requirements are 45.6 VDC to 50.4 VDC, with a maximum of 3.5 A. This model also features a warm-up time of 30 minutes and requires calibration at least once every 2 years to maintain accuracy and performance.

    “`

    Specification Detail
    Part Numbers 782857-01, 782956-01
    Model PXIe-4112
    Category PXI Programmable Power Instruments
    Channels 2
    Voltage Range 60 V
    Current Range 1 A
    Minimum Programmable Voltage Level/Limit 0.1 V
    Minimum Programmable Current Level 0.01 A
    Output Power 60 W/channel (Total 120 W)
    Software Compatibility LabVIEW, LabWindows/CVI, Microsoft Visual C/C++
    Power Requirements 0.5 A from 3.3 V rail, 0.25 A from 12 V rail
    Auxiliary Power Source Input Requirements 45.6 VDC to 50.4 VDC, 3.5 A max
    Warm-Up Time 30 minutes
    Calibration Period At least once every 2 years
    Analog Output Voltage Range 0 V to

    Question 1: What is the voltage range of the PXIe-4112?
    Answer 1: Up to 60V

    Question 2: How many channels does the PXIe-4112 have?
    Answer 2: 2 channels

    Question 3: What is the required calibration interval for the PXIe-4112?
    Answer 3: Every 2 years

    Question 4: What is the minimum programmable voltage level for the PXIe-4112?
    Answer 4: 0.1 V

    Question 5: What software is compatible with the PXIe-4112?
    Answer 5: LabVIEW, LabWindows/CVI, Microsoft Visual C/C++