The National Instruments PXIe-4300 is a 16-bit, 8-channel differential analog input module with a 250 kS/s sample rate and 300 V channel isolation.

In Stock | Ships Today

img

    Description

    The National Instruments PXIe-4300 PXI Analog Input Module, part number 781337-01, is a high-performance module designed for use in the SC Express category. This module is specifically engineered to provide exceptional data acquisition capabilities with its 16 Bit resolution and 8 differential analog input Channels. It offers a high sample rate of 250 kS/s, making it suitable for capturing fast transient signals and various other applications requiring high-speed data acquisition.

    The PXIe-4300 is notable for its robust voltage rating of 300 V and features advanced safety measures including 300 Vrms CAT II channel isolation and 3,300 Vrms ground channel isolation for 5 seconds. These features ensure the module’s reliability and safety in challenging electrical environments. Additionally, the module includes low programmable pass filtering and DC input coupling for versatile signal processing capabilities.

    For enhanced data acquisition control and synchronization, the module supports digital input triggering via two PFI lines. It is fully compatible with the NI-DAQmx driver, facilitating easy integration and programming within National Instruments’ software ecosystem. The PXIe-4300 connects via a 96-pin male DIN 41612/IEC 60603-2 connector, ensuring secure and reliable physical connections to PXI systems.

    This module is designed to be efficient in its power usage, requiring only 2.0 W at +3.3 V and 8.8 W at +12 V, making it an energy-efficient choice for many systems. Its compact physical dimensions of 6.3 x 3.9 in allow for easy installation in PXI chassis, ensuring it fits well in space-constrained environments without compromising on performance.

    Question 1: What is the resolution of the PXIe-4300?
    Answer 1: 16 Bit

    Question 2: What sample rate does the PXIe-4300 offer?
    Answer 2: 250 kS/s

    Question 3: How many analog input channels does the PXIe-4300 have?
    Answer 3: 8 differential channels

    Question 4: What type of connectivity does the PXIe-4300 use?
    Answer 4: 96-pin male DIN 41612/IEC 60603-2 connector

    Question 5: What is the power requirement for the PXIe-4300?
    Answer 5: 2.0 W at +3.3 V, 8.8 W at +12 V

    Specification Detail
    Part Number 781337-01
    Category SC Express
    Model PXIe-4300
    Description National Instruments PXIe-4300 PXI Analog Input Module
    Resolution 16 Bit
    Channels 8 differential analog input Channels
    Sample Rate 250 kS/s
    Voltage Rating 300 V
    Channel Isolation 300 Vrms CAT II channel isolation, 3,300 Vrms ground channel isolation for 5 seconds
    Filtering Low programmable pass filtering, DC input coupling
    Digital Input Triggering Two PFI lines
    Driver NI-DAQmx
    Connector 96-pin male DIN 41612/IEC 60603-2
    Power Requirements 2.0 W at +3.3 V, 8.8 W at +12 V
    Physical Dimensions 6.3 x 3.9 in