Description
The part number for this product is 153917A-01L (782878-01), classified under the SC Express category. It is a PXIe-4322 model, specifically a National Instruments PXIe-4322 PXI Analog Output Module. This module boasts a 16-Bit resolution and provides an 8-Channel Analog Output. It features integrated signal conditioning with channel to channel isolation, ensuring robust and reliable signal processing capabilities.
The module is designed with overvoltage protection of ±120 volts, safeguarding against unexpected power surges. It supports a high update rate of 250 kS/s per channel, which allows for rapid data transmission. Additionally, it has the capability to both source and sink current, offering versatile application use.
A brief warm-up time of 15 minutes is required for the module to operate at optimum levels, with a calibration recommended at least once a year to maintain accuracy. The timing accuracy of the module is within 50 ppm of the sample rate, and it possesses a timing resolution of 10 nanoseconds, ensuring precise control over output signals.
The module’s output FIFO buffer capacity stands at 8,191 samples, supporting both non-periodic and periodic AO waveform modes for flexible signal generation. It is compatible with NIDAQmx driver software, facilitating easy integration with existing systems. The physical characteristics include a weight of 5.7 oz, although the dimensions are not specified, indicating a lightweight and potentially compact design suitable for various applications.
| Specification | Detail |
|---|---|
| Part Number | 153917A-01L (782878-01) |
| Category | SC Express |
| Model | PXIe-4322 |
| Description | National Instruments PXIe-4322 PXI Analog Output Module |
| Resolution | 16-Bit |
| Channels | 8-Channel Analog Output |
| Signal Conditioning | Integrated with Channel to Channel Isolation |
| Overvoltage Protection | ±120 volts |
| Update Rate | 250 kS/s per channel |
| Current Capability | Source and Sink |
| Warm-up Time | 15 minutes |
| Calibration | Recommended at least once a year |
| Timing Accuracy | 50 ppm of sample rate |
| Timing Resolution | 10 nanoseconds |
| Output FIFO Buffer Capacity | 8,191 samples |
| AO Waveform Modes | Non-periodic and Periodic |
| Driver Software | NIDAQmx |
| Weight | 5.7 oz |
| Dimensions
Question 1: What is the resolution of the PXIe-4322? Answer 1: 16-Bit Question 2: How many analog outputs does the PXIe-4322 have? Question 3: What overvoltage protection does PXIe-4322 offer? Question 4: What is the update rate per channel for PXIe-4322? Question 5: How often is calibration recommended for the PXIe-4322? |