img

PCI-4452

The National Instruments PCI-4452, with part number 778317-01, is a dynamic signal acquisition device featuring Microsoft Excel integration, multiple communication interfaces including DAQ boards and GPIB instruments, differential inputs with configurable settings, and though declared obsolete

In Stock | Ships Today

img

    Description

    The National Instruments PCI-4452, with part number 778317-01, is integrated with a Measure function for Microsoft Excel, allowing for efficient data acquisition and control. This device supports a variety of communication interfaces, including DAQ boards, GPIB instruments, and RS-232 devices, and offers user-friendly dialog boxes for configuring measurements directly into Excel worksheet cells. The PCI-4452 is equipped with a digital I/O mating connector that is a 50-position connector and utilizes differential (DIFF) inputs, which can be configured as referenced single-ended (SE) channels using the BNC-2140 DSA accessory.

    For signal input, the NI PCI-4452 can handle both floating or ground-referenced modes and features a method to reduce common mode noise by grounding the negative input from floating sources. Moreover, the device includes a software programmable switch that allows for the signal path to be set for AC or DC coupling, depending on the user’s requirements. Despite being declared obsolete by National Instruments, the PCI-4452 remains available for purchase and repair through Apex Waves, ensuring long-term usability for existing setups.

    Feature Specification
    Part Number PCI-4452
    NI Part Number 778317-01
    Manufacturer National Instruments
    Measure Function Included for Microsoft Excel
    Communication Interfaces DAQ boards, GPIB instruments, RS-232 devices
    Configuration Dialog boxes for configuring measurements
    Integration Excel worksheet cells
    Digital I/O Mating Connector 50-position connector
    Input Type Differential (DIFF) inputs
    Single-Ended Configuration Referenced single-ended (SE) via BNC-2140 DSA accessory
    Input Modes Floating or ground-referenced
    Common Mode Noise Reduction Possible by grounding the negative input from floating sources
    Signal Path Switch Software programmable for AC/DC coupling
    Obsolete Status Announced by National Instruments but available for purchase and repairs by Apex Waves

    Question 1: How does the National Instruments PCI-4452 utilize its differential inputs and software programmable switch to reduce common mode noise and adapt to different signal sources?
    Answer 1: The National Instruments PCI-4452 is capable of handling both floating and ground-referenced input signal modes, and it can reduce common mode noise by grounding the negative input from floating sources; additionally, it integrates with Microsoft Excel through a Measure function that facilitates efficient data acquisition and control, allowing for the configuration of measurements directly into Excel worksheet cells.

    Question 2: What are the capabilities of the National Instruments PCI-4452 in terms of input signal modes and noise reduction, and how does it integrate with Microsoft Excel for data acquisition?
    Answer 2: The National Instruments PCI-4452 utilizes its differential inputs by allowing them to be configured as referenced single-ended channels, reducing common mode noise effectively when the negative input from floating sources is grounded, and it adapts to different signal sources using a software programmable switch to set the signal path for either AC or DC coupling, according to the user’s specific requirements.

    Question 3: What are the capabilities and long-term support options for the National Instruments PCI-4452, part number 778317-01, particularly regarding its integration with Microsoft Excel and input signal modes?
    Answer 3: The National Instruments PCI-4452, part number 778317-01, is capable of integrating with Microsoft Excel through its Measure function for efficient data acquisition and control, supports various communication interfaces such as DAQ boards, GPIB instruments, and RS-232 devices, and can handle floating or ground-referenced input signals with options for AC or DC coupling. Despite being obsolete, it remains supported for purchase and repair through Apex Waves, ensuring long-term usability for current systems.

    Question 4: What are the capabilities and features of the National Instruments PCI-4452, and how does Apex Waves support its long-term usability despite it being declared obsolete?
    Answer 4: The National Instruments PCI-4452 is a data acquisition and control device with a Measure function for Microsoft Excel, supporting DAQ boards, GPIB, and RS-232 interfaces, and offering easy configuration through Excel dialog boxes. It features a 50-position digital I/O mating connector with differential inputs that can be set as single-ended channels, handles both floating and ground-referenced signals with a method to reduce common mode noise, and includes a programmable AC/DC coupling switch. Despite its ob

    Question 5: What are the capabilities and features of the National Instruments PCI-4452, and what options are available for its continued use despite being declared obsolete?
    Answer 5: The National Instruments PCI-4452 is a data acquisition and control device that offers efficient integration with Microsoft Excel through its Measure function, supports multiple communication interfaces like DAQ boards, GPIB instruments, and RS-232 devices, and features user-friendly configuration dialog boxes for Excel, differential inputs with an option for referenced single-ended channels, and the ability to handle floating or ground-referenced signal modes with AC or DC coupling. Despite being declared obsolete by National Instruments, Apex Waves provides ongoing purchase and repair